| Electronic Components Datasheet Search |
|
ST90135 Datasheet(PDF) 172 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
ST90135 Datasheet(HTML) 172 Page - STMicroelectronics |
|
172 / 190 page ![]() 172/190 ST90158 - EIGHT-CHANNEL ANALOG TO DIGITAL CONVERTER (A/D) ANALOG TO DIGITAL CONVERTER (Cont’d) CONTROL LOGIC REGISTER (CLR) The Control Logic Register (CLR) manages the A/D converter logic. Writing to this register will cause the current conversion to be aborted and the autoscan logic to be re-initialized. CONTROL LOGIC REGISTER (CLR) R253 - Read/Write Register Page: 63 Reset Value: 0000 0000 (00h) Bit 7:5 = SC[2:0]: Start Conversion Address. These 3 bits define the starting analog input chan- nel (Autoscan mode). The first channel addressed by SC[2:0] is converted, then the channel number is incremented for the successive conversion, until channel 7 (111) is converted. When SC2, SC1 and SC0 are all set, only channel 7 will be converted. Bit 4 = EXTG: External Trigger Enable. This bit is set and cleared by software. 0: External trigger disabled. 1: External trigger enabled. Allows a conversion sequence to be started on the subsequent edge of the external signal applied to the EXTRG pin (when enabled as an Alternate Function). Bit 3 = INTG: Internal Trigger Enable. This bit is set and cleared by software. 0: Internal trigger disabled. 1: Internal trigger enabled. Allows a conversion se- quence to be started, synchronized by an inter- nal signal (On-chip Event signal) from a Multi- function Timer peripheral. Both External and Internal Trigger inputs are inter- nally ORed, thus avoiding Hardware conflicts; however, the correct procedure is to enable only one alternate synchronization input at a time. Note: The effect of either synchronization mode is to set the START/STOP bit, which is reset by hard- ware when in SINGLE mode, at the end of each sequence of conversions. Requirements: The External Synchronisation In- put must receive a low level pulse longer than an INTCLK period and, for both External and On-Chip Event synchronisation, the repetition period must be greater than the time required for the selected sequence of conversions. Bit 2 = POW: Power Up/Power Down. This bit is set and cleared by software. 0: Power down mode: all power-consuming logic is disabled, thus selecting a low power idle mode. 1: Power up mode: the A/D converter logic and an- alog circuitry is enabled. Bit 1 = CONT: Continuous/Single. 0: Single Mode: a single sequence of conversions is initiated whenever an external (or internal) trigger occurs, or when the ST bit is set by soft- ware. 1: Continuous Mode: the first sequence of conver- sions is started, either by software (by setting the ST bit), or by hardware (on an internal or ex- ternal trigger, depending on the setting of the INTG and EXTG bits); a continuous conversion sequence is then initiated. Bit 0 = ST: Start/Stop. 0: Stop conversion. When the A/D converter is running in Single Mode, this bit is hardware re- set at the end of a sequence of conversions. 1: Start a sequence of conversions. 70 SC2 SC1 SC0 EXT G INTG POW CON T ST 9 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |