Electronic Components Datasheet Search
  English  ▼
ALLDATASHEET.NET

X  

HD6432351 Datasheet(PDF) 619 Page - Renesas Technology Corp

Part # HD6432351
Description  16-Bit Single-Chip Microcomputer
PDF  1025 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  RENESAS [Renesas Technology Corp]
Direct Link  http://www.renesas.com
Logo RENESAS - Renesas Technology Corp

HD6432351 Datasheet(HTML) 619 Page - Renesas Technology Corp

Back Button HD6432351 Datasheet HTML 615Page - Renesas Technology Corp HD6432351 Datasheet HTML 616Page - Renesas Technology Corp HD6432351 Datasheet HTML 617Page - Renesas Technology Corp HD6432351 Datasheet HTML 618Page - Renesas Technology Corp HD6432351 Datasheet HTML 619Page - Renesas Technology Corp HD6432351 Datasheet HTML 620Page - Renesas Technology Corp HD6432351 Datasheet HTML 621Page - Renesas Technology Corp HD6432351 Datasheet HTML 622Page - Renesas Technology Corp HD6432351 Datasheet HTML 623Page - Renesas Technology Corp Next Button
Zoom Inzoom in Zoom Outzoom out
 619 / 1025 page
background image
Section 13 Serial Communication Interface (SCI)
Rev. 3.00 Sep 15, 2006 page 585 of 988
REJ09B0330-0300
In serial reception, the SCI operates as described below.
[1] The SCI monitors the transmission line, and if a 0 stop bit is detected, performs internal
synchronization and starts reception.
[2] The received data is stored in RSR in LSB-to-MSB order.
[3] The parity bit and stop bit are received.
After receiving these bits, the SCI carries out the following checks.
[a] Parity check:
The SCI checks whether the number of 1 bits in the receive data agrees with the parity
(even or odd) set in the O/
E bit in SMR.
[b] Stop bit check:
The SCI checks whether the stop bit is 1.
If there are two stop bits, only the first is checked.
[c] Status check:
The SCI checks whether the RDRF flag is 0, indicating that the receive data can be
transferred from RSR to RDR.
If all the above checks are passed, the RDRF flag is set to 1, and the receive data is stored in
RDR.
If a receive error* is detected in the error check, the operation is as shown in table 13.11.
Note: * Subsequent receive operations cannot be performed when a receive error has
occurred.
Also note that the RDRF flag is not set to 1 in reception, and so the error flags must
be cleared to 0.
[4] If the RIE bit in SCR is set to 1 when the RDRF flag changes to 1, a receive data full interrupt
(RXI) request is generated.
Also, if the RIE bit in SCR is set to 1 when the ORER, PER, or FER flag changes to 1, a
receive error interrupt (ERI) request is generated.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com