| Electronic Components Datasheet Search |
|
WM8352 Datasheet(PDF) 117 Page - Wolfson Microelectronics plc |
|
|
|||||||||||||||||||||||||||||
WM8352 Datasheet(HTML) 117 Page - Wolfson Microelectronics plc |
|
117 / 336 page ![]() Production Data WM8352 w PD, February 2011, Rev 4.4 117 14.5 CUSTOM MODES The WM8352 provides three custom start-up modes. These are selected by setting the CONF1 and CONF0 pins = 01, 10 or 11. The custom mode start-up sequences define the following parameters: Polarity of the ON pin (Active low or high) Configuration of the USB power source Configuration of the Watchdog timer mode Configuration of the Control Interface mode Configuration of the 32kHz oscillator (enabled or disabled) Configuration of the real-time-clock (enabled or disabled) Configuration of LDO1 Selection of crystal oscillator detect mode (see Section 14.3.6) Configuration of the voltage settings and start-up timeslots for DC-DC and LDO supplies Configuration of GPIO pins In Development Mode, the RECONFIG_AT_ON register bit (see Section 14.4.2) may be used to control the device configuration behaviour. In Custom Modes 01, 10 or 11, the default setting (RECONFIG_AT_ON = 1) must always be used. Setting this bit to 0 may result in erroneous behaviour and deviation from the custom configuration settings. The custom modes do not allow configuring the WM8352 in the OFF state. As a result, evaluation and debugging in custom modes is limited. 14.5.1 CONFIGURATION MODE 01 In Configuration Mode 01, the following general default settings apply: PARAMETER REGISTER SETTING DESCRIPTION ON polarity ON_POL = 1 ON pin is Active Low USB power source USB_SLV_500MA = 1 Selects 500mA limit in USB slave Watchdog timer WDOG_MODE [1:0] = 00 Watchdog is disabled Control Interface SPI_3WIRE = 0 SPI_4WIRE = 0 SPI_CFG = 0 Control Interface is 2-wire mode 32kHz oscillator OSC32K_ENA = 1 32kHz Oscillator is enabled Real Time Clock RTC_TICK_ENA = 1 RTC_CLKSRC = 0 Real Time Clock is enabled LDO1 LDO1_PIN_MODE = 0 LDO1_PIN_EN = 0 LDO1 controlled as normal via register bits Crystal detect mode Crystal detect mode is not enabled. The default voltages and the power-up sequence for all DC-DCs and LDOs in Configuration Mode 01 are shown below in Table 65 and Figure 66. The time delay between each time slot is approximately 1.28ms. Note that the Limit Switch is not enabled automatically in Configuration Mode 01; as a result, the Limit Switch remains open when the WM8352 enters the ACTIVE state. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |