16 / 33 page ![]() TSL2581, TSL2583 LIGHT-TO-DIGITAL CONVERTER TAOS134A − JULY 2012 15 The LUMENOLOGY r Company r r Copyright E 2012, TAOS Inc. www.taosinc.com ID Register (12h) The ID register provides the value for both the part number and silicon revision number for that part number. It is a read-only register whose value never changes. Table 11. ID Register 6 75 4 REVNO 2 31 0 PARTNO Address 12h Reset − − Bit : FIELD BITS DESCRIPTION PARTNO 7:4 Part Number Identification: field value 1001b REVNO 3:0 Revision number identification ADC Channel Data Registers (14h − 17h) The ADC channel data are expressed as 16-bit values spread across two registers. The ADC channel 0 data registers, DATA0LOW and DATA0HIGH provide the lower and upper bytes, respectively, of the ADC value of channel 0. Registers DATA1LOW and DATA1HIGH provide the lower and upper bytes, respectively, of the ADC value of channel 1. All channel data registers are read-only and default to 00h on power up. Table 12. ADC Channel Data Registers REGISTER ADDRESS BITS DESCRIPTION DATA0LOW 14h 7:0 ADC channel 0 lower byte DATA0HIGH 15h 7:0 ADC channel 0 upper byte DATA1LOW 16h 7:0 ADC channel 1 lower byte DATA1HIGH 17h 7:0 ADC channel 1 upper byte The upper byte data registers can only be read following a read to the corresponding lower byte register. When the lower byte register is read, the upper eight bits are strobed into a shadow register, which is read by a subsequent read to the upper byte. The upper register will read the correct value even if additional ADC integration cycles end between the reading of the lower and upper registers. NOTE: The Read Word protocol can be used to read byte-paired registers. For example, the DATA0LOW and DATA0HIGH registers (as well as the DATA1LOW and DATA1HIGH registers) may be read together to obtain the 16-bit ADC value in a single transaction Manual Integration Timer Registers (18h − 19h) The MANUAL INTEGRATION TIMER registers provide the number of cycles in 10.9 μs increments that occurred during a manual start/stop integration period. The timer is expressed as a 16-bit value across two registers. See CONTROL and TIMING Registers for further instructions in configuring a manual integration. The maximum time that can be derived without an overflow is 714.3 ms. Table 13. Manual Integration Timer Registers 6 75 4 2 31 0 TIMER Address 18h 19h Reset 00h Bit : REGISTER ADDRESS BITS DESCRIPTION TIMERLOW 18h 7:0 Manual Integration Timer lower byte TIMERHIGH 19h 7:0 Manual Integration Timer upper byte |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |