| Electronic Components Datasheet Search |
|
ZADCS0882 Datasheet(PDF) 20 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
ZADCS0882 Datasheet(HTML) 20 Page - List of Unclassifed Manufacturers |
|
20 / 27 page ![]() ZADCS0882/0842/0822 8-Bit, 300ksps, ADC Family Data Sheet October 12, 2011 © 2011 Zentrum Mikroelektronik Dresden AG — Rev. 2.0 All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner. The information furnished in this publication is PRELIMINARY and subject to changes without notice. 20 of 26 Figure 13: 16-Clock External Clock Mode Conversion nCS Figure 14: 11-Clock External Clock Mode Conversion Internal Clock Mode In Internal Clock Mode, the conversion starts at the falling clock edge of the eighth control bit just as in External Clock Mode. However, there are no further clock pulses required at SCLK to complete the conversion. The conversion clock is generated by an internal oscillator that runs at approximately 3.3MHz. While the conversion is running, the SSTRB signal is driven LOW. As soon as the conversion is complete, SSTRB is switched to HIGH, signalling that the conversion result can be read out on the serial interface. To shorten cycle times ZADCS08x2 family devices allow interleaving of the read out process with the transmission of a new control byte. Thus it is possible to read the conversion result and to start a new conversion with just two consecutive byte transfers, instead of thee bytes that would have to be send without the interleaving function. While the IC is performing a conversion in Internal Clock Mode, the Chip Select signal (nCS) may be tied HIGH allowing other devices to communicate on the bus. The output driver at DOUT is switched into a high impedance state while nCS is HIGH. The conversion time tCONV may vary in the specified limits depending on the actual VDD and temperature values. 16-Clocks per Conversion Interleaving of the data read out process and transmission of a new Control Byte is also supported for External Clock Mode operation. Figure 13 shows the transmission timing for conversion runs using 16 clock cycles per run. 11-Clocks per Conversion ZADCS08x2 family devices do also support an 11 clock cycle conversion mode (see Figure 14). This is the fastest conversion mode possible. In fact, the specified converter sampling rate of 300ksps will be reached in this mode, provided the clock frequency is set to 3.3MHz. Usually micro controllers do not support this kind of 11 bit serial communication transfers. However, specifically designed digital state machines implemented in S A2 A1 A0 UNI/ BIP SGL/ DIF PD1 PD0 B7 B6 B5 B4 B3 B2 B1 B0 Zero filled Acquire Idle Conversion Idle (MSB) (LSB) 1 8 1 8 1 8 SCLK 1 A0 UNI/ BIP (Start) DIN SSTRB DOUT S A2 A1 SGL/ DIF PD1 PD0 Acquire B7 B6 nCS S A2 A1 A0 UNI/ BIP SGL/ DIF PD1 PD0 B7 B6 B5 B4 B3 B2 B1 Zero filled Acquire Idle Conversion (MSB) (LSB) 1 8 1 11 (Start) SCLK DIN SSTRB DOUT S A2 A1 A0 UNI/ BIP SGL/ DIF PD1 PD0 Acquire B7 B6 11 1 B0 B5 B4 B3 B2 B1 B0 S A2 Conversion A1 A0 UNI/ BIP SGL/ DIF |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |