3 / 16 page ![]() AN2678 M41T82-83-93 series RTCs 3/16 1.3 Measuring FT and the timing error For the analog calibration, a frequency counter is recommended. This will provide the highest accuracy. The next consideration is using the microprocessor’s timer. This can be used to adjust the analog calibration and will be used for the digital portion. Microprocessor timers can come in a variety of configurations with many different speeds and input options, so this document can only address them in a general sense. Figure 1 shows the basic setup between the RTC and the microprocessor. The processor's timer is used to measure the frequency of the RTC's frequency test signal (FT) and then adjust the RTC's calibration registers as necessary via the I2C bus. Figure 1. Basic setup of microprocessor and RTC Fundamentally, the processor needs to measure the period of the timer and calculate the error or frequency deviation of the FT signal, but the measurement process is itself prone to error. However, it should be possible to minimize that error to an acceptable level. The key concept is that the microprocessor's timer runs off a clock signal derived from the microprocessor's oscillator with AT cut crystal. Since this oscillator has low drift over temperature, the timer’s clock signal will be low drift, too. Thus, using this timer, the RTC can be calibrated to approach the accuracy of this timing chain, thus reducing the timekeeping errors associated with watch crystals due to temperature drift. In Figure 2, the microprocessor's clock is called TCLK, and is used to sample the 512 Hz frequency test signal, FT. Each sample includes some uncertainty. But the uncertainty does not change as more samples are added. Thus, with many samples, the uncertainty will be very small in comparison to the measured period. For example, in Figure 2, the timer can detect that a transition occurred on the FT signal between two successive samples, but it cannot determine exactly where between those samples that it occurred. That uncertainty is labeled Tε1, Tε2 and Tε3 in the figure. RTC TIMER OSC OSC AT cut crystal Watch crystal FT = 512Hz I2C 2 uP ACAL DCAL ai13995 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |