5 / 16 page ![]() Preliminary Information MT9042 3-101 Automatic Mode In normal AUTOMATIC mode operation, the RSEL input is set to 0. This will allow the state machine to control PLL operation and select the reference input based on the state of the LOSS1 and LOSS2 inputs (see state transitions in Table 4). If the PRI reference signal is lost (LOSS1 = HIGH, LOSS2 = LOW), then the PLL will enter HOLDOVER mode immediately and stay there for a time determined by the RC time constant connected to the Guard Time input (GTi, GTo). When the primary reference signal has not been regained and the guard time has been exceeded, the reference will be switched to SEC. The time constant determined by the RC circuit connected to the GTi input provides the hysteresis on automatic switching between PRI and SEC during very short interruptions of the primary reference signal. The Guard Time, tgt, can be predicted using the step response of an RC network. The capacitor voltage on the RC circuit is described by an exponential curve. When the capacitor voltage reaches the positive going threshold of GTi (typically 1.77 volts for Schmitt trigger TTL inputs, see Figure 4) a logic HIGH level results. This causes the state machine to move from the holdover state of PRI to the state of using SEC as the input reference. The following equation can be used to determine the Guard Time tgt: VGTi 1.77v time Figure 4 - a) RC circuit for guard time, R ( Ω) C (f) GTi GTo (a) (b) b) exponential waveform on GTi tgt t gt RC V dd 1.77 – V dd ------------------------- ln – = The state machine will continue to monitor the LOSS1 input and will switch back to the PRI reference once the primary reference becomes functional as indicated by the LOSS1 input. A logic level HIGH on both the LOSS1 or LOSS2 inputs indicates that none of the external references are available. Under these circumstances, the PLL will be switched into the HOLDOVER state (within a specified rate of frame slip) until a fuIly functional reference input is available. Time Interval Error Correction Circuit (TIE) The TIE correction circuit generates a virtual input synchronized to the selected primary input reference. After a reference rearrangement the TIE corrects the phase of this new reference in such a way that the virtual input preserves its phase. In other words, reference switching will not create significant phase changes on the virtual input, and therefore, the outputs of the PLL. The TIE reset (TRST) aligns the falling edge of the current input with the falling edge of the primary input reference. When TRST is held LOW for at least 100 ns, the next falling edge of the reference input becomes aligned and passes through the TIE circuit without additional delay. PLL Measures of Performance To meet the requirements of AT & T TR62411 and ETSI 300 011, the following PLL performance parameters were measured: • locking range and lock time • slip rate in holdover mode • free-run accuracy • maximum time interval error and slope • intrinsic jitter • jitter transfer function • output jitter spectrum • wander FSEL 2 FSEL 1 Input Reference Frequency 00 Reserved 01 8 kHz 10 1.544 MHz 11 2.048 MHz Table 5 - Input Frequency Selection of the MT9042 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |