| Electronic Components Datasheet Search |
|
E5CZ-R2MT Datasheet(PDF) 29 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E5CZ-R2MT Datasheet(HTML) 29 Page - Omron Electronics LLC |
|
29 / 64 page ![]() E5 @Z 29 M M M M M M M M M M M M M M M M M M M M M in-l 0 P dp 0 P in-t 5 P in-h 100 P d-u c P sl-h 1300 C sl-l -200 C cntl onof P s-hc stnd P st on P cp 20 P c-cp 20 P oreV or-r P alt1 2 P alt2 2 P alt3 2 P tr-t off P tr-h 100.0 P tr-l 0.0 P o1-t 4-20 P amov 0 P PID ON/OFF ST (self-tuning) M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M init off P ev-m 1 P ev-1 none P ev-2 stop P mspu off P spru m P rest a P al1n n-o P alh1 0.2 C al2n n-o P alh2 0.2 C al3n n-o P alh3 0.2 C hbu on P hbl off P hbh 0.1 P st-b 15.0 C alfa 0.65 P inf 0.0 P pvad off P o-dp off P ret off P a1lt off P a2lt off P a3lt off P prlt 3 P sero off P cjc on P rlrv off P a1on 0 P a2on 0 P a3on 0 P a1of 0 P a2of 0 P a3of 0 P istp ins1 P amad off hsu on P hsl off P hsh 0.1 P lba 0 P lbal 8.0 C lbab 3.0 C out1 o P alm1 alm1 P alm2 alm2 P α Initial Setting Level Advanced Function Setting Level Press the O Key for at least 1 s. Press the O Key less than 1 s. Input type Scaling upper limit Scaling lower limit Decimal point For input type of analog Temperature unit °C, °F For input type of temperature SP upper limit SP lower limit Standard or heating/cooling For input type of tem- perature, standard control, or PID When assigning PID or control output to pulse output Control period (heating) Set the pulse output cycle. Control period (cooling) Direct/reverse operation Alarm 1 type Alarm 3 type Alarm 2 type Transfer output type Linear output Transfer output upper limit Transfer output lower limit Linear current output Linear output Move to advanced function setting level Displayed when initial setting/ communications protection is set to 0. Move by setting password ( −169). Parameter initialization Number of multi-SP uses Two SPs: 1 Four SPs: 2 Event input assignment 1 Event input assignment 2 Multi-SP uses SP ramp time unit Standby sequence reset Alarm 1 open in alarm Alarm 1 hysteresis Alarm 2 open in alarm Alarm 2 hysteresis Alarm 3 open in alarm Alarm 3 hysteresis Heater burnout latch HB ON/OFF Heater burnout hysteresis ST stable range Input digital filter Additional PV display MV display Automatic display return time Alarm 1 latch Alarm 3 latch Alarm 2 latch Move to protect level time Input error output Cold junction compen- sation method MB command logic switching Alarm 1 ON delay Alarm 3 ON delay Alarm 2 ON delay Alarm 1 OFF delay Alarm 3 OFF delay Alarm 2 OFF delay Input shift type Auto/manual select addition HS alarm use HS alarm latch HS alarm hysteresis LBA detection time LBA level LBA band Control output 1 assignment Alarm output 1 assignment Alarm output 2 assignment M csel on P Character select Limit the set point M alm3 alm3 P Alarm output 3 assignment (E5AZ/E5EZ only) |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |