Back Button LM98725CCMT/NOPB Datasheet HTML 17Page - Texas Instruments LM98725CCMT/NOPB Datasheet HTML 18Page - Texas Instruments LM98725CCMT/NOPB Datasheet HTML 19Page - Texas Instruments LM98725CCMT/NOPB Datasheet HTML 20Page - Texas Instruments LM98725CCMT/NOPB Datasheet HTML 21Page - Texas Instruments LM98725CCMT/NOPB Datasheet HTML 22Page - Texas Instruments LM98725CCMT/NOPB Datasheet HTML 23Page - Texas Instruments LM98725CCMT/NOPB Datasheet HTML 24Page - Texas Instruments LM98725CCMT/NOPB Datasheet HTML 25Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 21 / 145 page
background image
LM98725
www.ti.com
SNAS474H – APRIL 2009 – REVISED MARCH 2015
•
Set SSCG Enable (Page 2, Register 0x1A, Bit 0) = 1 (enable spreading, load spreading state machines)
•
Lock Registers (Page 0, Register 0, Bit 0 = 1)
•
If spreading is synchronized to SH interval, the spreading function will wait until the next SH Interval before
beginning.
•
Set SSCG Enable (Page 2, Register 0x1A, Bit 0) = 1 (enable spreading, load spreading state machines)
•
Lock Registers (Page 0, Register 0, Bit 0 = 1)
•
If spreading is synchronized to SH interval, the spreading function will wait until the next SH Interval before
beginning.
7.3.10.4 Changing SSCG Settings
To Change SSCG Settings:
•
Un-Lock Registers ((Page 0, Register 0, Bit 0 = 0)
•
Set SSCG Enable = 0 (disable spreading)
•
Change desired SSCG settings.
•
Set SSCG Enable = 1 (enable spreading, reload spreading state machines)
•
Lock Registers (Page 0, Register 0, Bit 0 = 1)
Table 2. SSCG and Clock Multiplication Register Settings
PAGE
REGISTER
DEFAULT
BITS
NAME
DESCRIPTION
2
24
18
1111 1000
[7:5]
Master PLL Range Setting for PLL1 and PLL2 when
Autorange is off. Set to 111.
[4:3]
PLL1 Charge Pump Current Control
PLL Control 1
Default = 11
[2:0]
PLL1 Filter Bandwidth Control
Default = 000
2
25
19
0001 1000
[7:5]
Reserved
Default = 000
[4:3]
PLL2 Charge Pump Current Control
Default = 11
PLL Control 2
Set to 00 when using SSCG.
[2:0]
PLL2 Filter Bandwidth Control
Default = 000
Set to 111 when using SSCG.
Copyright © 2009–2015, Texas Instruments Incorporated
Submit Documentation Feedback
21
Product Folder Links: LM98725



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com