21 / 31 page ![]() 21/27 Datasheet Datasheet BM1P105FJ TSZ02201-0F2F0A200170-1-2 2.Oct.2013.Rev.001 © 2013 ROHM Co., Ltd. All rights reserved. www.rohm.com TSZ22111・15・001 ● Operation modes of protection circuit Table 3 lists the operation mode of each protection function. Table 3. Operation Modes of Protection Circuit Function Operation mode VCC Undervoltage Locked Out Auto recovery VCC Overvoltage Protection Auto recovery (with 100-us timer) FB Over Limited Protection Auto recovery (with 64-us timer) CS OPEN Protection Auto recovery (with 100-us timer) ● Sequence The sequence for this IC is shown in Figure 31. A transition to OFF mode occurs under all conditions when VCC exceeds 8.2 V. Soft Start1 Soft Start4 Burst & Low Power MODE Normal MODE OFF MODE OLP MODE ( Pulse Stop) CS OPEN MODE ( Pulse Stop) VCC OVP ( Pulse Stop) Soft Start2 Soft Start3 Figure 31. Sequence Diagram |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|