| Electronic Components Datasheet Search |
|
SLAD4.100 Datasheet(PDF) 1 Page - PULS GmbH |
|
|
|||||||||||||||||||||||||||||
SLAD4.100 Datasheet(HTML) 1 Page - PULS GmbH |
|
1 / 4 page ![]() slad4e100 / 071026 1/ 4 EMC and Low Volt. Directive AS-Interface DC/DC converter with 4A SLAD4.100 • Input: DC 24V • Output: 30.55V / 4A • AS Interface data decoupling • For highly demanding industrial applications The primary switched mode DIN rail DC/DC converter SLAD4.100 specif- ically supplies AS Interface systems with energy. The AS-Interface bus technology allows to connect up to 62 participants to a control and to supply them with energy with a single two-conductor cable. When connecting slaves, the yellow AS-Interface cable offers the high degree of protection IP67 in conjunction with the insulation displace- ment. The communication signals of the individual network participants are modulated onto the supply voltage. For this purpose, specific DC/DC converter units with integrated data decoupling are required for AS-Interface systems. Order information Order number Description SLAD4.100 SLZ10 ZM1.Wall ZM11.SIDE AS-Interface DC/DC converter DIN-Rail bracket for S7-300 Simatic-Rail Wall mounting bracket Side mounting bracket Short description Input Rated voltage DC 24V Input voltage range 18.0-32.4Vdc Continuous operation See Fig.2 14.0-18.0Vdc max. 60 seconds or with derating max. 36.0 Vdc Absolute maximum continuous input voltage with no damage to the DC/DC converter. Allowed voltage be- tween input and earth (ground) max. 60Vdc or 42.4Vac Allowed input ripple voltage max. 5Vpp, 47Hz-40kHz, the momentary input voltage must always be within the specified limits. Turn-on voltage typ. 17.5Vdc Steady-state value Reverse input polarity protection Included, unit does not start when input voltage is reversed Shut down voltage typ. 14.0Vdc Steady-state value typ. 35Vdc Steady-state value Input current typ. 5.6A at 24Vdc input and output 30.55V, 4A Inrush current Max. 1.8A peak at -25°C up to +70°C Inrush energy Typ. < 1A2s at -25°C up to +70°C Start-up delay typ. 650ms Rise time typ. 100ms constant current load 4A typ. 200ms constant current load 4A with external 5mF capacitor Integrated internal fuse T10A HBC ( not accessible) External capacitors on the input voltage bus are allowed without any limitations. Output Rated voltage DC 30.55V +/- 3% ( not adjustable ) Rated current 4A Input / output separation SELV IEC / EN 60950-1 PELV IEC 60364-4-41, EN 60204-1, IEC 62103 Double or reinforced insulation, Max. allowed voltage between any input pin and ground: 60Vdc or 42.4Vac Current limitation > 4.4A Overload behaviour Continous current, see Fig. 3 Short-circuit current min. 5A , max. 9A Load regulation < 250mV Static value, 0A 4A 0A Line regulation < 5mV Input variations between 18 to 32.4Vdc Ripple < 50mVpp ( 500kHz bandwith, 50 Ohm meas- urement, ohmic load) Noise (spikes) < 100mVpp ( 20Hz to 20MHz bandwith, 50 Ohm measurement, ohmic load Over-voltage protection Max. 36V Operating indicator Green LED (extinguishes at overload) Output is protected against short-circuit, open circuit and overload. Use AS-Interface DC/DC converters only together with AS-Interface lines. ® |
Similar Part No. - SLAD4.100 |
|
Similar Description - SLAD4.100 |
|
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |