7 / 9 page ![]() 2004 November 8 7 LPC2124 Philips Semiconductors Single Chip 32-bit Microcontroller Erratasheet Affected features: 1. Interrupt on Match for Timer0/1. 2. Interrupt on Capture for Timer0/1. 3. These same features will be affected when using PWM. Workaround: There is no clear workaround for this problem but some of the below mentioned solutions could work with some applications. Possible workarounds for Match functionality: 1. If the application only needs two Match registers then distribute them between Timer 0 and Timer 1 to avoid this problem 2. Stop the timer before accessing the Interrupt register for clearing the interrupt and then start timer again after the access is completed. 3. Polling for interrupt: Supposing that there are two Match events (Match X and Match Y). At the end of the Interrupt Service Routine (ISR) for Match X, compare the Timer Counter value with the Match Register Y value. If the Timer Counter value is more than the Match Register Y value then it is possible that this event might have been missed. In this case jump to the ISR directly and service Match event Y. Possible workarounds for Capture functionality: 1. Try to spread the capture events between both timers if there are two capture events. If the application also has a match event then one of the capture events may suffer 2. Polling for Capture: At the end of a Match interrupt ISR or Capture event ISR compare the previous Capture value with the current Capture value. If the Capture value has changed then the Capture event might have been missed. In this case, jump to the ISR directly and service the Capture event. The same above workarounds will also be applicable for the Match and Compare functionality of the PWM block. Core.1 Incorrect update of the Abort Link register in Thumb state Introduction: If the processor is in Thumb state and executing the code sequence STR, STMIA or PUSH followed by a PCrelative load, and the STR, STMIA or PUSH is aborted, the PC is saved to the abort link register. Problem: In this situation the PC is saved to the abort link register in word resolution, instead of half-word resolution. Conditions: The processor must be in Thumb state, and the following sequence must occur: <any instruction> <STR, STMIA, PUSH> <---- data abort on this instruction |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |