| Electronic Components Datasheet Search |
|
MXD2020GL Datasheet(PDF) 5 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
MXD2020GL Datasheet(HTML) 5 Page - List of Unclassifed Manufacturers |
|
5 / 7 page ![]() MEMSIC MXD2020GL/ML/NL/HL Page 5 of 7 2002.08.29.1 Resolution: The accelerometer resolution is limited by noise. The output noise will vary with the measurement bandwidth. With the reduction of the bandwidth, by applying an external low pass filter, the output noise drops. Reduction of bandwidth will improve the signal to noise ratio and the resolution. The output noise scales directly with the square root of the measurement bandwidth. The maximum amplitude of the noise, its peak- to- peak value, approximately defines the worst case resolution of the measurement. With a simple RC low pass filter, the rms noise is calculated as follows: Noise (mg rms) = Noise(mg/ Hz ) * ) 6 . 1 * ) ( ( Hz Bandwidth The peak-to-peak noise is approximately equal to 6.6 times the rms value (for an average uncertainty of 0.1%). DIGITAL INTERFACE The MXD2020GL/HL/ML/NL is easily interfaced with low cost microcontrollers. For the digital output accelerometer, one digital input port is required to read one accelerometer output. For the analog output accelerometer, many low cost microcontrollers are available today that feature integrated A/D (analog to digital converters) with resolutions ranging from 8 to 12 bits. In many applications the microcontroller provides an effective approach for the temperature compensation of the sensitivity and the zero g offset. Specific code set, reference designs, and applications notes are available from the factory. The following parameters must be considered in a digital interface: Resolution: smallest detectable change in input acceleration Bandwidth: detectable accelerations in a given period of time Acquisition Time: the duration of the measurement of the acceleration signal DUTY CYCLE DEFINITION The MXD2020GL/HL/ML/NL has two PWM duty cycle outputs (x,y). The acceleration is proportional to the ratio T1/T2. The zero g output is set to 50% duty cycle and the sensitivity scale factor is set to 20% duty cycle change per g. These nominal values are affected by the initial tolerance of the device including zero g offset error and sensitivity error. This device is offered from the factory programmed to either a 10ms period (100 Hz) or a 2.5ms period (400Hz). T1 Length of the “on” portion of the cycle. T2 (Period) Length of the total cycle. Duty Cycle Ratio of the “0n” time (T1) of the cycle to the total cycle (T2). Defined as T1/T2. Pulse width Time period of the “on” pulse. Defined as T1. T2 T1 A (g)= (T1/T2 - 0.5)/20% 0g = 50% Duty Cycle T2= 2.5ms or 10ms (factory programmable) Figure 3: Typical output Duty C ycle CHOOSING T2 AND COUNTER FREQUENCY DESIGN TRADE-OFFS The noise level is one determinant of accelerometer resolution. The second relates to the measurement resolution of the counter when decoding the duty cycle output. The actual resolution of the acceleration signal is limited by the time resolution of the counting devices used to decode the duty cycle. The faster the counter clock, the higher the resolution of the duty cycle and the shorter the T2 period can be for a given resolution. Table 2 shows some of the trade-offs. It is important to note that this is the resolution due to the microprocessors’ counter. It is probable that the accelerometer’s noise floor may set the lower limit on the resolution. T2 (ms) MEMSIC Sample Rate Counter- Clock Rate (MHz) Counts Per T2 Cycle Counts per g Reso- lution (mg) 2.5 400 2.0 5000 1000 1.0 2.5 400 1.0 2500 500 2.0 2.5 400 0.5 1250 250 4.0 10.0 100 2.0 20000 4000 0.25 10.0 100 1.0 10000 2000 0.5 10.0 100 0.5 5000 1000 1.0 Table 2: Trade-Offs Between Microcontroller Counter Rate and T2 Period. USING THE ACCELEROMETER IN VERY LOW POWER APPLICATIONS (BATTERY OPERATION) In applications with power limitations, power cycling can be used to extend the battery operating life. One important consideration when power cycling is that the accelerometer turn on time limits the frequency bandwidth of the accelerations to be measured. For example, operating at 3.0V the turn on time is 40mS. To double the operating time, a particular application may cycle power ON for 40mS, then OFF for 40mS, resulting in a measurement period of 80mS, or a frequency of 12.5Hz. With a frequency of measurements of 12.5Hz, accelerations changes as high as 6.25Hz can be detected. Power cycling can be used effectively in many inclinometry applications, where inclination changes can be slow and infrequent. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |