| Electronic Components Datasheet Search |
|
R58ECRGB1Q. Datasheet(PDF) 4 Page - Banner Engineering Corp. |
|
|
|||||||||||||||||||||||||||||
R58ECRGB1Q. Datasheet(HTML) 4 Page - Banner Engineering Corp. |
|
4 / 11 page ![]() Wiring Diagrams 3 1 2 4 5 10-30V dc Remote Teach Load Load + – Key 1 = Brown 2 = White 3 = Blue 4 = Black 5 = Gray Quick disconnect (QD) wiring diagrams are functionally identical. Sensor Configuration The R58E is pre-set to power up in Run mode and to sense the most recently taught registration mark. Quickly optimize the sensitivity of the R58E using one of two available TEACH modes: Static TEACH or Dynamic TEACH. Static TEACH: Both the Output ON and Output OFF conditions are presented, and sensitivity can be adjusted manually using the push buttons. Dynamic TEACH: The registration mark is presented during actual sensing conditions, and the sensitivity can be adjusted manually using the push buttons. Remote TEACH Configure the sensor either using the push buttons, or using a remote switch. Remote configuration also may be used to enter Setup mode to set the ON- and OFF-delay, and to disable the push buttons to prevent unauthorized adjustment of the configuration settings. To access this feature, connect the gray wire of the sensor to 0 V dc, with a remote switch between the sensor and 0 V dc. Follow the sequence of input pulses to configure the sensor (see the procedures in this document). The duration of each pulse (corresponding to a push button “click”), and the period between multiple pulses, are defined as: “T”: 0.04 seconds ≤ “T” ≤ 0.8 seconds. Push Button Enable/Disable (Lockout) In addition to its configuration function, the remote input may be used to disable the push buttons for security. Disabling the push buttons prevents unauthorized adjustment of the configuration settings. Connect the gray wire of the sensor as described in Wiring Diagrams on page 4, and four-pulse to either enable or disable the push buttons (0.04 seconds < "T" < 0.8 seconds): Note: Push buttons can be disabled/enabled from the remote line only. Static TEACH In Static TEACH mode, the sensor learns two sensing conditions after each is presented one time. The sensor automatically positions the switchpoint midway between the two conditions. The sensor returns to Run mode if either TEACH condition is not registered within 60 seconds. The sensor reverts to the previous taught conditions. Cancel TEACH mode by pressing and holding the Static push button for ≥ 2 seconds. The sensor reverts to the previous taught conditions (that is, exit without saving). Static TEACH and Manual Adjust Sensitivity may be adjusted at any time when the sensor is in Run mode by clicking the “+” and “-” buttons. Each click translates to 1/2 segment on the signal strength bargraph display. For best sensing reliability, both sensing conditions should register equally distant from the switchpoint on the signal strength bargraph display. Sensor positions threshold midway between taught conditions Output OFF Output ON 2nd Taught Condition 1st Taught Condition Position adjusted by Manual Adjust Figure 5. Static TEACH (Light Operate Shown) R58E Series Expert™ Registration Mark Sensors 4 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 122928 Rev. D |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |