| Electronic Components Datasheet Search |
|
R58ECRGB1Q. Datasheet(PDF) 5 Page - Banner Engineering Corp. |
|
|
|||||||||||||||||||||||||||||
R58ECRGB1Q. Datasheet(HTML) 5 Page - Banner Engineering Corp. |
|
5 / 11 page ![]() 1. Access TEACH mode. Method Action Result Push Button2 Press and hold Static (-) for > 2 seconds. LO and DO: Alternately flash green Output: On amber (indicating ready to teach first sensing condition) Bargraph display: Turns off Remote Input3 No action required; sensor is ready for the first sensing condition. N/A 2. Teach the first sensing condition. Method Action Result Push Button a. Present the first sensing condition. b. Click Static (-). LO and DO: Alternately flash green Output: Off (indicating ready to teach the second sensing condition) Bargraph display: Remains off Remote Input a. Present the first sensing condition. b. Single-pulse the remote input. c. Wait at least 8 seconds. T 3. Teach the second sensing condition. Method Action Result Push Button a. Present the second sensing condition. b. Click Static (-). Teach Accepted • The bargraph display flashes one segment for three seconds to indicate relative contrast (see Table 1 on page 6) . • The sensor enters Run mode. Teach Not Accepted • Pairs of bargraph display segments flash for three seconds to indicate low contrast. • The sensor returns to TEACH the first sensing condition. Remote Input a. Present the second sensing condition. b. Single-pulse the remote input. T Dynamic TEACH Dynamic TEACH is used to configure sensitivity during actual sensing conditions, when looking for a mark against its background condition. The R58E takes multiple samples of the registration mark against its background material and automatically positions the threshold at the optimum level. The registration mark must be presented at least two times during Dynamic TEACH. When Dynamic TEACH is used, the Output ON state is the shorter duration (smaller) event sensed, and LO/DO is set accordingly. To change the output state, change to either LO or DO in Setup mode, or pulse the remote line three times. Sensor positions threshold midway between taught conditions Output OFF Output ON Darkest Taught Condition Lightest Taught Condition Position adjusted by Manual Adjust Figure 6. Dynamic TEACH (Light or Dark Operate, depending on the sensing condition shown) Maximum Feed Rate To optimize performance and to ensure that all LED color and gain combinations are evaluated during Dynamic TEACH, the registration mark must encompass the 1.2 mm dimension of the 1.2 mm x 3.8 mm sensing image for at least 0.002 seconds. Determine the maximum feed rate using the following formula: 2 0.04 seconds ≤ “click” ≤ 0.8 seconds 3 0.04 seconds ≤ “T” ≤ 0.8 seconds R58E Series Expert™ Registration Mark Sensors P/N 122928 Rev. D www.bannerengineering.com - Tel: +1-763-544-3164 5 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |