9 / 37 page ![]() 7.3 Feature Description 7.3.1 Power Up After power-up or general-call reset, the TMP144 immediately starts a conversion as shown in Figure 7-1. The active conversion time (tACT) of the device is 26 ms (typical) and the first result is available after the conversion is complete in the temperature result register. Startup tCONV tACT Start of Conversion Figure 7-1. Conversion Start 7.3.2 Digital Temperature Output The TMP144 by default provides a 12-bit digital output for each temperature conversion, which is stored in the temperature result register. The host application needs to read two bytes to obtain the data. Additionally, the application may program the ETM bit in the configuration register to get a 13-bit digital output. Table 7-1 summarizes the temperature output format. One LSB equals 0.0625 °C resolution. Table 7-1. Temperature Data Format TEMPERATURE (°C) DIGITAL OUTPUT (ETM = 0) DIGITAL OUTPUT (ETM = 1) BINARY (T11-T0) HEX BINARY (T12-T0) HEX +150 0111 1111 1111 7FF 0 1001 0110 0000 0960 +127.9375 0111 1111 1111 7FF 0 0111 1111 1111 07FF +125 0111 1101 0000 7D0 0 0111 1101 0000 07D0 +100 0110 0100 0000 640 0 0110 0100 0000 0640 +80 0101 0000 0000 500 0 0101 0000 0000 0500 +75 0100 1011 0000 4B0 0 0100 1011 0000 04B0 +50 0011 0010 0000 320 0 0011 0010 0000 0320 +25 0001 1001 0000 190 0 0001 1001 0000 0190 +0.0625 0000 0000 0001 001 0 0000 0000 0001 0001 0 0000 0000 0000 000 0 0000 0000 0000 0000 -0.0625 1111 1111 1111 FFF 1 1111 1111 1111 1FFF -25 1110 0111 0000 E70 1 1110 0111 0000 1E70 -40 1101 1000 0000 D80 1 1101 1000 0000 1D80 7.3.3 Timeout Function A timeout mechanism is implemented on the TMP144 to allow for re-synchronization of the SMAART Wire™ interface if synchronization between the host and the TMP144 is lost for 28 ms (typical). If the timeout period expires between the calibration byte and the command byte, between the command byte and a data byte, or between any data bytes, the TMP144 resets the SMAART Wire™ interface circuitry and waits for the baud rate calibration command to restart. Every time a byte is transmitted on the SMAART Wire™ interface, this timeout period restarts. www.ti.com TMP144 SBOS891A – OCTOBER 2018 – REVISED FEBRUARY 2021 Copyright © 2021 Texas Instruments Incorporated Submit Document Feedback 9 Product Folder Links: TMP144 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |