2 / 13 page ![]() cui.com date 01/18/2022 │ page 2 of 13 CUI Inc │ SERIES: PBO-1 │ DESCRIPTION: AC-DC POWER SUPPLY INPUT parameter conditions/description min typ max units voltage 85 70 305 430 Vac Vdc frequency 47 63 Hz current at 115 Vac at 277 Vac 0.12 0.06 A A inrush current at 115 Vac at 277 Vac 9 15 A A no load power consumption 24 Vdc output models all other models 0.3 0.25 W W OUTPUT parameter conditions/description min typ max units capacitive load 5 Vdc output models all other models 220 100 µF µF initial set point accuracy 5 Vdc output models all other models ±8 ±5 % % line regulation at full load ±1.5 % load regulation from 5~100% load 24 Vdc output models all other models ±6 ±3 % % hold-up time at 230 Vac 150 180 ms switching frequency 100 kHz temperature coefficient ±0.15 %/°C PROTECTIONS parameter conditions/description min typ max units over current protection auto recovery 110 500 % short circuit protection continuous, auto recovery SAFETY & COMPLIANCE parameter conditions/description min typ max units isolation voltage input to output for 1 minute 3,000 Vac safety approvals certified to 62368: IEC/EN certified to 60950: UL/cUL safety class Class II conducted emissions CISPR32/EN55032, Class A (recommended circuit 1,2,6) CISPR32/EN55032, Class B (recommedned circuit 3,4,5) radiated emissions CISPR32/EN55032, Class A (recommended circuit 1,2,6) CISPR32/EN55032, Class B (recommended circuit 3,4,5) ESD IEC/EN61000-4-2, contact ±4 kV, perf. Criteria B radiated immunity IEC/EN61000-4-3, 10V/m, perf. Criteria A EFT/burst IEC/EN61000-4-4, ±2 kV, (recommended circuit 1,2,3), perf. Criteria B IEC/EN61000-4-4, ±4 kV, (recommended circuit 4,5,6), perf. Criteria B surge IEC/EN61000-4-5, line to line ±1 kV, Class B (recommended circuit 1,2), perf. Criteria B IEC/EN61000-4-5, line to line ±2 kV (recommended circuit 6), perf. Criteria B IEC/EN61000-4-5, line to line ±1 kV/line to ground ±2 kV (recommended circuit 3) perf. Criteria B IEC/EN61000-4-5, line to line ±2 kV/line to ground ±4 kV (recommended circuit 4,5) perf. Criteria B conducted immunity IEC/EN61000-4-6 Class A, 10 Vr.m.s, perf. Criteria A Additional Resources: Product Page | 3D Model | PCB Footprint |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |