29 / 72 page ![]() DS12195 Rev 7 29/72 TDA7803A Functional description 71 When the amplifier is biased and the IB4 D0 = "1", the permanent diagnostic is enabled. The turn-on diagnostic state is held until an over current event is triggered. When this happens, a new diagnostic cycle can start. 6.3 Permanent diagnostic The detectable faults are (see Table 5 for definitions): Short to GND Short to Vs Short across the speaker Then the following additional features are also provided: Input offset detection AC diagnostic When an over current event occurs, TDA7803A has two different cycles that could react with: Restart cycle: it is a 2 ms pulse. During this period a check of the output is performed. Plateau cycle: it is an 80 ms cycle. During this period a check of the outputs is performed and the results of diagnostic analysis are written into the I2C bus. TDA7803A has two different operating behaviors when an over current event is detected: Restart mode, (IB4 D0 = "0"). The diagnostic is not enabled. Each audio channel operates independently from each other. If any of the above mentioned faults occurs, only the channel(s) where the fault happened is shut down. The diagnostic performs restart cycles every 2 ms until the fault condition is present. The amplifier restarts in play only once the overload is removed. In Restart mode reporting diagnostic results are turned off and the corresponding bits in the channels’ data byte registers will be reset accordingly. Diagnostic mode, (IB4 D0 = "1"). It is enabled via I2C and self activated if an output overload occurs to the speaker outputs. If any of the above mentioned faults occurs, Ihigh Test current for the short load pulse - 200 40 -mA For speaker mode For line driver mode Ilow Test current for the open load pulse - 40 2 - mA For speaker mode For line driver mode 1. For typical loudspeaker of 2 and 4 ohm. 2. These numbers are evaluated in simulation. 3. Typical values for 4 Ω and 2 Ω and zero offset. These numbers depend on the loudspeaker and also on the intrinsic offset of the amplifier. For 2 Ω loudspeaker, -30 mV offset and Fs = 48 kHz TRU = 21.2 ms; for 4 Ω and same surrounding conditions TRU = 22.1 ms. Under these conditions TPL = 122.4 ms for 2 Ω and 124.4 for 4 Ω. For higher values the number are not reported here. Table 6. Start-up pulse typical timings (Fs = 48 kHz) (continued) Symbol Parameter Min Typ Max Unit Note |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |