9 / 18 page ![]() Specifications are subject to change without notice WM30 96 DS 240914 9 WM30 96 Standard compliance Safety IEC60664, IEC61010-1 EN60664, EN61010-1 EN62052-11. Metrology EN62053-22, EN62053-23, EN50470-3. Pulse output DIN43864, IEC62053-31 Approvals Eligible System performance Meter for Go Solar California, CE, cULus “Listed” Connections Screw-type Cable cross-section area max. 2.5 mm2. min./max. screws tightening torque: 0.4 Nm / 0.8 Nm. Suggested screws tightening torque: 0.5 Nm Housing DIN Dimensions (WxHxD) Module holder: 96x96x50mm. “A” and “B” type modules: 89.5x63x16mm. “C” type module: 89.5x63x20mm. Max. depth behind the panel With 3 modules (A+B+C): 81.7 mm Material ABS/Nylon PA66, self- extinguishing: UL 94 V-0 Mounting Panel mounting Protection degree Front IP65, NEMA4x, NEMA12 Screw terminals IP20 Weight Approx. 420 g (packing included) Operating temperature -25°C to +55°C (-13°F to 131°F) (R.H. from 0 to 90% non-condensing @ 40°C) according to EN62053-21, EN50470-1 and EN62053- 23 Storage temperature -30°C to +70°C (-22°F to 158°F) (R.H. < 90% non- condensing @ 40°C) according to EN62053-21, EN50470-1 and EN62053- 23 Installation category Cat. III (IEC60664, EN60664) Insulation (for 1 minute) See “Insulation between inputs and outputs” table Dielectric strength 4kVAC RMS for 1 minute Noise rejection CMRR 100 dB, 48 to 62 Hz EMC According to EN62052-11 Electrostatic discharges 15kV air discharge Immunity to irradiated Test with current: 10V/m from 80 to 2000MHz Electromagnetic fields Test without any current: 30V/m from 80 to 2000MHz Burst On current and voltage measuring inputs circuit: 4kV Immunity to conducted disturbances 10V/m from 150KHz to 80MHz Surge On current and voltage measuring inputs circuit: 4kV; on “L” auxiliary power supply input: 1kV Radio frequency suppression According to CISPR 22 General specifications Insulation between inputs and outputs (1): respect another module 4kV, in the same module 0kV. -: combination not allowed. NOTE: all the models have, mandatory, to be connected to external current transformers because the isolation among the current inputs is just functional (100VAC). PowerSupply (HoL) Mesuring inputs Relèoutput (MOR2) Staticouput (MOO2) Serialport Ethernetport Analogue outputs PowerSupply (HoL) - 4kV 4kV 4kV 4kV 4kV 4kV Mesuringinputs 4kV - 4kV 4kV 4kV 4kV 4kV Relèoutput (MOR2) 4kV 4kV 2kV - 4kV 4kV 4kV Staticouput (MOO2) 4kV 4kV - 2kV 4kV 4kV 4kV Serialport 4kV 4kV 4kV 4kV - - 4kV Ethernetport 4kV 4kV 4kV 4kV - - 4kV Analogueoutputs 4kV 4kV 4kV 4kV 4kV 4kV 4kV(1) |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |