9 / 39 page ![]() Analog Integrated Circuit Device Data Freescale Semiconductor 9 33800 ELECTRICAL CHARACTERISTICS STATIC ELECTRICAL CHARACTERISTICS CONSTANT CURRENT SOLENOID DRIVER OUTPUT (CCD2_OUT) (CONTINUED) CCD2 Pull Up Current Pull-up enabled, DAC = 000, CCD1OUT = CCD1REC = 2.0V ICCD2(PULLUP) -60 -40 -20 µA CCD2 Pull Down Current Pull-up disabled, DAC = 000, CCD2OUT = CCD2REC = 2.0V ICCD2(PULLDOWN) 20 40 60 µA OCTAL SERIAL DRIVERS (OUT1 - 8) Drain-to-Source ON Resistance (OUT1 - 2) IOUT = 0.350A, TJ = 125°C, VPWR = 13V IOUT = 0.350A, TJ = 25°C, VPWR = 13V IOUT = 0.350A, TJ = -40°C, VPWR = 13V RDS (ON) – – – – 0.7 – 1.4 – – Ω Drain-to-Source ON Resistance (OUT3 - 8) IOUT = 0.350A, TJ = 125°C, VPWR = 13V IOUT = 0.350A, TJ = 25°C, VPWR = 13V IOUT = 0.350A, TJ = -40°C, VPWR = 13V RDS (ON) – – – – 1.0 – 1.7 – – Ω Output Self Limiting Current Output 3 to Output 8 Output 1, Output 2 IOUT(LIM) 1.0 4.0 – – 2.0 6.0 A Output Fault Detection Voltage Threshold.(7) Outputs Programmed OFF VOUT(FLTTH) 2.0 2.5 3.0 V Output OFF Open Load Detection Current VDrain = 18V, Outputs Programmed OFF IOCO 40 75 100 µA Output Clamp Voltage Low Side Drive ID = 20mA VOC 50 55 60 V Output Leakage Current VDD = 5.0V, VDrain = 24V, Open Load Detection Current Disabled VDD = 5.0V, VDrain = VOC - 1.0V, Open Load Detection Current Disabled VDD = 0V, VDrain = 24V, Device Disabled IOUT(LKG) – – – – – – 20 3000 10 µA Over-temperature Shutdown(8) TLim 155 – 185 °C Over-temperature Shutdown Hysteresis(8) TLim(HYS) 5.0 10 15 °C SPI DIGITAL INTERFACE (SO, SI, CS, SCLK) Input Logic High-voltage Thresholds(8) VIH 0.7 x VDD – VDD + 0.3 V Input Logic Low-voltage Thresholds(8) VIL GND - 0.3 – 0.2 x VDD V Input Logic Voltage Hysteresis(8) VHYS 100 – 300 mV Input Logic Capacitance(8) CIN – – 20 pF Sleep Mode Input Logic Current(8) VDD = 0.0V ILOGICSS -10 – 10 µA Notes 7. Output fault detection thresholds with outputs programmed OFF. Output fault detect thresholds are the same for output open and shorts. 8. This parameter is guaranteed by design, however is not production tested. Table 3. Static Electrical Characteristics Characteristics noted under conditions 3.0V ≤ V DD ≤ 5.5V, 9.0V ≤ VPWR ≤ 18V, - 40°C ≤ TA ≤ 125°C, GND = 0V, unless otherwise noted. Typical values noted reflect the approximate parameter means at TA = 25°C under nominal conditions, unless otherwise noted. Characteristic Symbol Min Typ Max Unit |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |