| Electronic Components Datasheet Search |
|
AHT10 Datasheet(PDF) 6 Page - ASAIR All Rights Reserved. |
|
|
|||||||||||||||||||||||||||||
AHT10 Datasheet(HTML) 6 Page - ASAIR All Rights Reserved. |
|
6 / 13 page ![]() 2.2 Storage conditions and operating instructions Humidity sensitivity level ( MSL ) is 1 , based on IPC/JEDEC J-STD-020 standard. Therefore, it is recommended to use it within one year after shipment. Humidity sensors are not ordinary electronic components and require careful protection. This must be taken seriously by users. Prolonged exposure to high concentrations of chemical vapor will cause the sensor reading to drift. It is recommended to store the sensors ESD original package comprises a sealed bag, and meet the following conditions: Temperature range 1 0 ℃ -50 ℃ (0-85 deg.] C for a limited time); humidity of 20-60% RH (no ESD Package Sensor). For sensors that have been removed from the original packaging, we recommend storing them in the inner metal. Anti-static bag made of PET/AL/CPE material. Sensors should be avoided during production and transportation High concentrations of chemical solvents and prolonged exposure. Avoid contact with volatile glue, tape, stickers or volatile packaging materials. Such as foam, foam and so on. The production area should be well ventilated. 2.3 recovery processing As described above, if the sensor is exposed to extreme conditions or chemical vapors, readings generated drift. It can be restored to the calibration state by the following processing. Drying: maintained at 80-85 ° C and <5% RHhumidity for 10 hours; Rehydration: 12 hours at 20-30 ° C and >75% RH humidity. 2.4 temperature effects The relative humidity of a gas depends to a large extent on temperature. Therefore, when measuring humidity, it should be ensured that all sensors measuring the same humidity work at the same temperature. When testing, ensure that the sensor under test and the reference sensor are at the same temperature and then compare the humidity readings. If the sensor is on the same printed circuit board as the heat-generating electronic components, measures should be taken to minimize the effects of heat transfer when designing the circuit. In addition, when the measurement frequency is too high, the sensor's own temperature will rise and affect the measurement accuracy. If it is to ensure that its own temperature rise is less than 0.1 ° C , the activation time of AHT10 should not exceed the measurement time. 10% - recommended every 2 seconds measurement data once. 2.5 Materials for sealing and packaging Many materials absorb moisture and act as a buffer, which increases response time and hysteresis. Therefore, the material around the sensor should be carefully selected. The recommended materials are: metal, LCP, POM (Delrin), PTFE (Teflon), PE, PEEK , PP, PB, PPS, PSU, PVDF, PVF . For sealing and gluing (the conservative recommendation): recommended p ackage, or an electronic component using a silicone resinfilled epoxy. The gases released by these materials may also contaminate AHT10 (see2.2). Therefore, the sensor should be assembled last and placed in a well-ventilated area or dried in an environment > 50 ° C for 24 hours to allow the release of contaminated gases prior to packaging. 2.6 wiring rules and signal integrity If the SCL and SDA signal lines are parallel and very close to each other, it may cause signal crosstalk and communication failure. The solution is to place VDD and / or GND between |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |