| Electronic Components Datasheet Search |
|
AHT10 Datasheet(PDF) 10 Page - ASAIR All Rights Reserved. |
|
|
|||||||||||||||||||||||||||||
AHT10 Datasheet(HTML) 10 Page - ASAIR All Rights Reserved. |
|
10 / 13 page ![]() Figure 13 Start Transfer Status ( S ) - When SCL is high, SDA transitions from high to low. The start state is a special bus state controlled by the host, indicating the start of the slave transfer ( after the Start , the BUS bus is generally considered to be busy) Figure 14 Stop Transfer Status ( P ) - When SCL is high, the SDA line transitions from low to high. The stop state is a special bus state controlled by the master that indicates the end of the slave transfer ( after the Stop , the BUS bus is generally considered to be idle). 5.3 send command After the transmission is initiated, the subsequently transmitted I 2 C first byte includes the 7 -bit I 2 C device address 0x38 and one SDA direction (read R : '1' , write W : '0' ). After the first falling edge of the SCL clock 8, by pulling the SDA pin (ACK bit), indicating proper reception of the sensor. After issuing the initialization command ( '1110'0001' represents initialization, '1010'1100' stands for temperature and humidity measurement), the MCU must wait for the measurement to be completed. The basic commands are summarized in Table 9 . Table 10 shows the status bit descriptions returned by the slave. command Interpretation Code Initialization command Keep the host 1110’0001 Trigger measurement Keep the host 1010’1100 Soft reset 1011’1010 Table 9 basic command set Bit significance description Bit[7] Busy indication 1 -- 0 -- The device is busy, the device is in the measurement state, and the device is idle. Bit[6:5] Current working mode (Mode Status) 00 01 1x Currently NOR Currently CYC Currently CMD mode mode mode Bit[4] Reserved Reserved Bit[3] Calibration enable bit CAL Enable 1-calibrated 0-- not calibrated Bit[2:0] Reserved Reserved Table 10 status bit description Trigger measurement data ACK S Start P Stop Note: The sensor takes time to collect . After the host sends a measurement command ( 0xAC ) , the delay is over 75ms and the converted data is read and the returned status bit is normal. If the status bit [Bit7 of] is 0 for the data can be read normally, the sensor 1 is the busy state, the host needs to wait for the data processing is completed. 5.4 Soft reset This command (see Table 9 ) is used to restart the sensor system without turning the power off and on again. After receiving this command, the sensor system begins to reinitialize and restores the default settings. The soft reset takes less than 20ms S 0 1 1 1 0 0 0 0 1 0 1 0 1 1 0 0 I2C address +write Trigger measurement 0xac 00110011 00000000 P DATA0 DATA1 读取温湿度数据 S x x x x I2C address +read 状态 x x x x x x x x x x x x x x x x Humidity data Humidity data x x x x x x x x x x x x x x x x Humidity dataTemperature data Temperature data Temperatur e 主机到从机 从机到主机 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |