24 / 46 page ![]() L7250 24/46 2.7.2 Open Loop Commutation After position sense is complete, the microcontroller commutates the motor following a constant acceleration profile until sufficient BEMF is developed to reliably measure it. The starting position of the open loop commutation, determined by the position sense routine, is set up by first initializing the Memory Address Counter using LOADCP (*1), then clocking ADVANCE (*2) the appropriate number of times (8 pulses per 6 state position). The spindle state will be OLCOAST while setting the initial state. Then, drivers are enabled in either OL_SIX or OL_SIN modes (*3) , depending on whether 6 state or sine mode open loop commutation is desired. Once the motor is accelerated up to an appropriate speed (*4) , the motor is tri-stated by transitioning to the OLCOAST (*5) and then CLCOAST states, as described below, to synchro- nize the Smoothdrive system to the motor. Figure 5. Open Loop Commutation 2.7.3 Synchronization to Smoothdrive Commutation When the open loop commutation is complete, the drivers are put in OLCOAST mode, and after a delay for set- ting the Bemf sampling period, CLCOAST is asserted, so that a ZC Period (Tc, the time between two BEMF zero crossings) can be detected and measured. The BEMF sampling period is set in OLCOAST (*1) and after a delay (30 usec ) a Load CP (*2) is asserted. After a delay of time Tc0 (300usec suggested) another Load CP is asserted (*3); this initializes the electrical period for BEMF sampling. Once pregrammed the transition to CLCOAST (*4) , the BEMF is sampled at the rate of Tc0 to look for two consecutive LOW readings (in anticipation of the LOW->HI zero crossing transition (*5) ). After the first ZC rising edge, the BEMF sampling period is refreshed to Tc0 value. If two consecutive ZC edges are detected (*6), then after the last rising edge the Smoothdrive commutation is synchronized with the motor rotor position and it is ready to be programmed in closed loop commutation . At least two ZCs must be observed before transitioning to closed loop spinup (CLSIX or CLSIN) (*7a or *7b) . This ensures that the Smoothdrive circuitry is synchronized to the spindle motor. Set Load Coarse Phase Write Reg.07H LoadCP = 1 (*1) Set ADVANCE Write Reg.07H Advance = 1 Nadv=Nalign Inc Nadv START Open Loop Commutation Nadv=0 , i=0 Note2: Nalign is received from the Inductive Sense routine Indicating the rotor position alignement Accelerate in Sine or Six Set Open Loop SINE Write Reg.03H Spstate[3:0] =0011 Set Open Loop SIX Write Reg.03H Spstate[3:0] =0010 Set ADVANCE Write Reg.07H Advance = 1 Wait the End of RAMP_DELAY[ i ] Inc i i = RAMP_Steps Set OLCOAST Write Reg.03H Spstate[3:0]=0001 EXIT Open Loop Commutation (*2) (*3) (*4) (*5) SINE SIX Note1: Spstate[3:0] condition has been set in OLCOAST by the Inductive Sense Routine |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |