11 / 18 page ![]() 11/18 M48T559Y For more information on calibration, see the Appli- cation Note AN934 "TIMEKEEPER Calibration". The IRQ/FT pin is an open drain output which re- quires a pull-up resistor for proper operation. A 500-10k Ω resistor is recommended in order to control the rise time. SETTING ALARM CLOCK Registers 1FF5h-1FF2h contain the alarm set- tings. The alarm can be configured to go off at a prescribed time on a specific day of the month or repeat every day, hour, minute, or second. It can also be programmed to go off while the M48T559Y is in the battery back-up mode of operation to serve as a system wake-up call. RPT1-RPT4 put the alarm in the repeat mode of operation. Table 11 shows the possible configura- tions. Codes not listed in the table default to the once per second mode to quickly alert the user of an incorrect alarm setting. Note: User must transition address (or toggle chip enable) to see Flag bit change. When the clock information matches the alarm clock settings based on the match criteria defined by RPT1-RPT4, AF (Alarm Flag) is set. If AFE (Alarm Flag Enable) is also set, the alarm condi- tion activates the IRQ/FT pin. To disable alarm, write ’0’ to the Alarm Date registers and RPT1-4. The alarm flag and the IRQ/FT output are cleared by a read to the Flags register as shown in Figure 11. Note: If an alarm condition occurs while the flags register address is latched into the address buffer, the alarm flag will not be set until an address other than the flags register (1FF0h) is latched into the address buffer. This will insure that the alarm flag will not be inadvertently reset while reading the flag register. To properly check to see if an alarm condition has occurred while reading the flag reg- ister, the user is required to latch, read or write to an alternate address and then re-read the alarm flag. The IRQ/FT pin can also be activated in the bat- tery back-up mode. The IRQ/FT will go low if an alarm occurs and both ABE (Alarm in Battery Back-up Mode Enable) and AFE are set. The ABE and AFE bits are reset during power-up, therefore an alarm generated during power-up will only set AF. The user can read the Flag Register at system boot-up to determine if an alarm was generated while the M48T559Y was in the deselect mode during power-up. Figure 12 illustrates the back-up mode alarm timing. Figure 10. Interrupt Reset Waveforms AI01677B AD0-AD7 ACTIVE FLAG BIT ADDRESS 1FF0h R IRQ/FT Table 11. Alarm Repeat Mode RPT4 RPT3 RPT2 RPT1 Alarm Activated 1 1 1 1 Once per Second 1 1 1 0 Once per Minute 1 1 0 0 Once per Hour 1 0 0 0 Once per Day 0 0 0 0 Once per Month |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |