IMAGE SENSOR SOLUTIONS
35
Climatic Requirements
ITEM
DESCRIPTION
MIN.
MAX.
UNITS
CONDITIONS
NOTES
Operation to Specification
Temperature
-25
+40
oC
@ 10% ±5% RH
1, 2
Humidity
10±5
86±5
%RH
@ 36 ±2oC Temp.
1, 2
Operation Without Damage
Temperature
-50
+70
oC
@ 10% ±5% RH
2, 3
Storage
Temperature
-55
+70
oC
@ 10% ±5%RH
2, 4
Humidity
-----
95±5
%RH
@ 49 ±2oC Temp.
2, 4
Table 11 Climatic Requirements
Notes:
1.
The image sensor shall meet the specifications of this document while operating at these conditions.
2.
The tolerance on all relative humidity values is provided due to limitations in measurement instrument accuracy.
3.
The image sensor shall continue to function but not necessarily meet the specifications of this document while
operating at the specified conditions.
4.
The image sensor shall meet the specifications of this document after storage for 15 days at the specified
conditions.
Quality Assurance and Reliability
4.2.1
Quality Strategy: All devices will conform to the specifications stated in this document. This is accomplished through
a combination of statistical process control and inspection at key points of the production process. Typical
specification limits are not guaranteed but provided as a design target. For further information refer to ISS application
Note MTD/PS-0292, Quality and Reliability.
4.2.2
Replacement: All devices are warranted against failures in accordance with the Terms of Sale. This does not include
failure due to mechanical and electrical causes defined as the liability of the customer below.
4.2.3
Liability of the Supplier: A reject is defined as an image sensor that does not meet all of the specifications in this
document upon receipt by the customer.
4.2.4
Liability of the Customer: Damage from mechanical (scratches or breakage), electrostatic discharge (ESD) damage,
or other electrical misuse of the device beyond the stated absolute maximum ratings, which occurred after receipt of
the sensor by the customer, shall be the responsibility of the customer.
4.2.5
Cleanliness: Devices are shipped free of mobile contamination inside the package cavity. Immovable particles and
scratches that are within the imager pixel area and the corresponding cover glass region directly above the pixel sites
are also not allowed. The cover glass is highly susceptible to particles and other contamination. Touching the cover
glass must be avoided. See ISS Application Note MTD/PS-0237, Cover Glass Cleaning for Image Sensors, for further
information.
4.2.6
ESD Precautions: Devices are shipped in static-safe containers and should only be handled at static-safe workstations.
See ISS Application Note MTD/PS-0224, Electrostatic Discharge Control, for handling recommendations.
4.2.7
Reliability: Information concerning the quality assurance and reliability testing procedures and results are available
from the Image Sensor Solutions and can be supplied upon request. For further information refer to ISS Application
Note MTD/PS-0292 Quality and Reliability.
4.2.8
Test Data Retention: Image sensors shall have an identifying number traceable to a test file. Test data shall be kept
for a period of 2 years after date of delivery.
4.2.9
Mechanical: The device assembly drawing is provided as a reference. The device will conform to the published
package tolerances.
KAI-1010/1011 Rev 8 •
www.k odak.com/go/imagers 585-722- 4385 imagers@kodak.com