| Electronic Components Datasheet Search |
|
PM6681ATR Datasheet(PDF) 29 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
PM6681ATR Datasheet(HTML) 29 Page - STMicroelectronics |
|
29 / 47 page ![]() PM6681A Monitoring and protections 29/47 8 Monitoring and protections 8.1 Power Good signals The PM6681A provides three independent Power Good signals: one for each switching section (PGOOD1/PGOOD2). PGOOD1/PGOOD2 signals are low if the output voltage is out of ± 10 % of the designed set point or during the soft-start, standby and shutdown mode. 8.2 Thermal protection The PM6681A has a thermal protection to preserve the device from overheating. The thermal shutdown occurs when the die temperature goes above +150 °C. In this case all internal circuitry is turned off and the power sections are turned off after the discharge mode. A power on reset or a toggle on the SHDN pin is necessary to restart the device. 8.3 Overvoltage protection When the switching output voltage goes over the OVP threshold (about 116 % of its nominal value), the low side MOSFET turns on. The LS MOSFET is kept on until the output voltage returns under the OVP threshold. 8.4 Undervoltage protection When the switching output voltage is below 70 % of its nominal value, a latched undervoltage protection occurs. In this case the switching section is immediately disabled and both switches are open. The controller enters in soft-end mode and the output is eventually kept to ground, turning low side MOSFET on. The undervoltage circuit protection is enabled only at the end of the soft-start. Once an overvoltage protection has been detected, a toggle on SHDN, EN1/EN2 pin or a power on reset is necessary to clear the undervoltage fault and starts with a new soft-start phase. Table 10. Protections and operatives modes Mode Conditions Description Overvoltage protection OUT1/OUT2 > 115 % of the nominal value LGATE1/LGATE2 pin is forced high until the output voltage is over the OVP threshold, LDO5 remains active. Undervoltage protection OUT1/OUT2 < 70 % of the nominal value LGATE1/LGATE2 is forced high after the soft-end mode, LDO5 remains active. Exit by a power on reset or toggling SHDN or EN1/EN2 Thermal shutdown TJ > +150 °C All circuitry off. Exit by a POR on VIN or toggling SHDN. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |