| Electronic Components Datasheet Search |
|
MAX11080 Datasheet(PDF) 25 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAX11080 Datasheet(HTML) 25 Page - Maxim Integrated Products |
|
25 / 27 page ![]() 12-Channel, High-Voltage Battery-Pack Fault Monitor ______________________________________________________________________________________ 25 PIN NUMBER NAME ACTION EFFECT Open (or Disconnected) The pin defaults to low due to the internal pulldown (see Note 7). The effect depends on the intended overvoltage setting. 20 OVSEL0 Short to Pin 21 • If pin 20 and pin 21 have the same intended value, there is no effect for the short. • If pin 20 and pin 21 have a different setting, the VAA is shorted to AGND. ALRML goes low. Open (or Disconnected) The pin defaults to low due to the internal pulldown (see Note 7). The effect depends on the intended overvoltage setting. 21 OVSEL1 Short to Pin 22 • If pin 21 and pin 22 have the same intended value, there is no effect for the short. • If pin 21 and pin 22 have a different setting, the VAA is shorted to AGND. ALRML goes low. Open (or Disconnected) The pin defaults to low due to the internal pulldown (see Note 7). The effect depends on the intended overvoltage setting. 22 OVSEL2 Short to Pin 23 • If pin 22 and pin 23 have the same intended value, there is no effect for the short. • If pin 22 and pin 23 have a different setting, the VAA is shorted to AGND. ALRML goes low. Open (or Disconnected) The pin defaults to low due to the internal pulldown (see Note 7). The effect depends on the intended overvoltage setting. 23 OVSEL3 Short to Pin 24 • If pin 23 is set high, there is no effect for the short. • If pin 23 is set low, the VAA is shorted to AGND. ALRML goes low. Open (or Disconnected) ALRML goes high. 24 VAA Short to Pin 25 ALRML goes low. Open (or Disconnected) VAA goes to approximately 100mV and ALRML is approximately 0.5V. There is no heartbeat if there is a one before the opening. 25 AGND Short to Pin 26 The device is in shutdown mode. ALRML is low. Open (or Disconnected) The pin is internally pulled down and the device goes to the shutdown mode. ALRML is low. 26 SHDN Short to Pin 27 ALRML goes high and stays high even if the short is removed. The internal detect circuit considers this a major failure and the part has to be repowered up to come out of this state. Open (or Disconnected) The signal at the ALRML cannot be seen by the host. 27 ALRML Short to Pin 28 ALRML goes high and stays high even if the short is removed. The internal detect circuit considers this a major failure and the part has to be repowered up to come out of this state. Open (or Disconnected) The delay between the fault condition and alarm setting (ALRML goes high) goes to the minimum. This means there is almost no delay. 28 CD Short to Pin 29 The delay between the fault condition and alarm setting (ALRML goes high) is approximately 4s, which is set by the internal watchdog. Table 4. FEMA Analysis (Note 5) (continued) |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |