Back Button AS8118 Datasheet HTML 13Page - ams AG AS8118 Datasheet HTML 14Page - ams AG AS8118 Datasheet HTML 15Page - ams AG AS8118 Datasheet HTML 16Page - ams AG AS8118 Datasheet HTML 17Page - ams AG AS8118 Datasheet HTML 18Page - ams AG AS8118 Datasheet HTML 19Page - ams AG AS8118 Datasheet HTML 20Page - ams AG AS8118 Datasheet HTML 21Page - ams AG Next Button
Zoom Inzoom in Zoom Outzoom out
 17 / 30 page
background image
Data Sheet AS8118
Revision 1.8, 15-Feb-05
Page 17 of 30
Calboard
Reference
Meter
AS8118
Meter
I
Figure 7
Basic calibration setup for comparison calibration method
The standard or reference meter pulses are counted between two or more pulses from the meter to be calibrated. Ideally the
sum of the pulses would exactly be the ratio between standard meter pulse rate and the pulse rate of the meter under test.
From the deviation the corrected Pulse_lev may be calculated.
Nr
Ni
*
)
ideal
(
lev
_
Pulse
)
corrected
(
lev
_
Pulse
=
,
Where Nr is the number of pulses counted from the standard or reference meter and Ni is the ratio between the pulse rates,
which is always >1. The formula for Ni is as follows:
Fcal
*
Fmon
)
ref
(
PR
Ni
=
,
This is assuming that the CAL pulse output is used for calibration. If the LED pulse output is used for calibration, the following
formula should be used:
Fled
)
ref
(
PR
Ni
=
The Pulse_lev (ideal) is calculated using the following formula:
435924
20
230
*
I
A
*
V
V
)
ideal
(
lev
_
Pulse
max
mains
=
It is important to note that the formula for Pulse_lev (corrected) above should not be confused with the formula in the
previous method of calibration for ‘Defined Current and Calibration Time’ method, where Ni and Nr are reversed.
Example
The reference meter has a pulse rate, which is 10,000 times greater than the pulse rate of the AS8118 CAL output. During a
calibration cycle we measure 11,000 pulses between two CAL pulses. Therefore the ideal pulse-level has to be changed by a
factor of 10,000/11,000 = 0.909.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com