139 / 336 page ![]() Production Data WM8352 w PD, February 2011, Rev 4.4 139 The status of the LDO Regulators can be indicated and monitored externally via a GPIO pin configured as /VCC_FAULT (see Section 20). When a GPIO pin is configured as /VCC_FAULT output, a logic low level on this pin indicates that there is a fault condition on one of the LDO Regulators, DC-DC Converters, or the Current Limit switch. The /VCC_FAULT output is configurable by the control fields in Register R215. The fields described in Table 88 determine which of the LDOs contribute to the /VCC_FAULT indication. An undervoltage or overvoltage condition on any unmasked LDO will cause the /VCC_FAULT output to be set to logic low. ADDRESS BIT LABEL DEFAULT DESCRIPTION R215 (D7h) VCC_FAULT 11 LDO4_FAULT 0 LDO4 fault mask for the /VCC_FAULT 0 = don't mask converter fault 1 = mask converter fault 10 LDO3_FAULT 0 LDO3 fault mask for the /VCC_FAULT 0 = don't mask converter fault 1 = mask converter fault 9 LDO2_FAULT 0 LDO2 fault mask for the /VCC_FAULT 0 = don't mask converter fault 1 = mask converter fault 8 LDO1_FAULT 0 LDO1 fault mask for the /VCC_FAULT 0 = don't mask converter fault 1 = mask converter fault Table 88 LDO Regulator /VCCFAULT mask bits 14.7.4 ADDITIONAL CONTROL FOR LDO1 By default, all DC Converters and LDOs are disabled in the OFF state. Additional control is provided to enable LDO1 to be configured differently, allowing it to be enabled in the OFF state, or else to be controlled by a GPIO pin configured as /LDO_ENA (see Section 20.2.2). These options are selected by setting the register fields described in Table 89. In practical applications, however, these options are set by the Config Mode settings and are not set by users. Operation of LDO1 in the OFF state is subject to the restriction that VOUT1 must be set to at least 1.8V. CONDITION DESCRIPTION LDO1_PIN_MODE = 0 LDO1 controlled as normal via register bits LDO1_PIN_MODE = 1 LDO1_PIN_EN = 0 LDO1 enabled at all times LDO1_PIN_MODE = 1 LDO1_PIN_EN = 1 LDO1 controlled by /LDO_ENA only Table 89 LDO1 Additional Control Note that LDO1 is always disabled in BACKUP and ZERO states. Note that, when LDO1_PIN_MODE = 1, then LDO1 only operates as determined by the LDO1_VSEL field. The Hibernate settings are ignored under this configuration. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |