| Electronic Components Datasheet Search |
|
WM8352 Datasheet(PDF) 145 Page - Wolfson Microelectronics plc |
|
|
|||||||||||||||||||||||||||||
WM8352 Datasheet(HTML) 145 Page - Wolfson Microelectronics plc |
|
145 / 336 page ![]() Production Data WM8352 w PD, February 2011, Rev 4.4 145 15.2.2 CURRENT LIMIT SWITCH BULK DETECTION CONTROL The Current Limit Switch can be connected to voltages which may be higher than the device LINE voltage. To support this capability, the switch is powered from the highest available voltage; this requires a bulk detection circuit in order to select the highest available voltage. The bulk detection circuit is always enabled whenever the Current Limit Switch is enabled. It is possible to control whether the bulk detection circuit is enabled or not when the Current Limit Switch is disabled. This is controlled in Active mode by the LS_PROT bit, and in Hibernate mode by the LS_HIB_PROT bit. Disabling the Bulk Detection circuit will reduce power consumption. It is important to note, however, that the Bulk Detection circuit should always be enabled if voltages greater than LINE could be present on IP or OP. This applies regardless of whether the Current Switch is open or closed. ADDRESS BIT LABEL DEFAULT DESCRIPTION R199 (C7h) Limit switch control 1 LS_HIB_PRO T 1 Controls the bulk detection circuit when Limit Switch is disabled in Hibernate mode. 0 = bulk detection disabled 1 = bulk detection enabled 0 LS_PROT 1 Controls the bulk detection circuit when Limit Switch is disabled in Active mode. 0 = bulk detection disabled 1 = bulk detection enabled Table 92 Current Limit Switch Bulk Detection Control 15.2.3 INTERRUPTS AND FAULT PROTECTION The response to an over-current condition is selectable. To prevent false alarms during short current surges, faults are only signalled if the fault condition persists. ADDRESS BIT LABEL DEFAULT DESCRIPTION R199 (C7h) Limit switch control 15:14 LS_ERRACT [1:0] 00 Current limit detection behaviour 00 = ignore 01 = disable switch 10 = shut down system 11 = shut down system Table 93 Fault Response for the Current Limit Switch The limit switch has its own first-level interrupt, OC_INT (see Section 24). This contains a single second-level interrupt, OC_LS_EINT, indicating an over-current condition. OC_LS_EINT can be masked by setting the IM_OC_LS_EINT bit. ADDRESS BIT LABEL DESCRIPTION R29 (1Dh) Over Current Interrupt Status 15 OC_LS_EINT Limit Switch Over-current interrupt. (Rising Edge triggered) Note: This bit is cleared once read. R37 (25h) Over Current Interrupt Mask 15 IM_OC_LS_EINT Mask bit for Limit switch over-current interrupt When set to 1, IM_OC_LS_EINT masks OC_LS_EINT in R29 and does not trigger an OC_INT interrupt when OC_LS_EINT is set). Table 94 Current Limit Switch Interrupts |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |