144 / 336 page ![]() WM8352 Production Data w PD, February 2011, Rev 4.4 144 15 CURRENT LIMIT SWITCH 15.1 GENERAL DESCRIPTION The WM8352 includes an on-chip Current Limit Switch to control external devices and to support hot- plugging of accessories and power supplies. When the switch is enabled, it normally has a low resistance, allowing current to pass through (from the IP pin to the OP pin). If the current limit threshold is reached, the WM8352 can raise an interrupt, disable the switch and/or shut down the whole device. 15.2 CONFIGURING THE CURRENT LIMIT SWITCH 15.2.1 CURRENT LIMIT SWITCH ENABLE The Current Limit Switch can be enabled in software using the register fields defined in Table 91. In Active mode, the Current Limit Switch can be enabled in software using the LS_ENA bit. Setting this bit whilst in the Pre-Active state (see Figure 65) will not immediately enable the Current Limit Switch; this bit will only become effective once the WM8352 has reached the Active state. The Current Limit Switch may be programmed to become enabled in a selected timeslot within the start-up sequence. When this happens, the WM8352 will set the LS_ENA bit. Note that setting the LS_ENSLOT field in software is only relevant to the Development Mode, as this field is assigned a preset value in each of the Custom Modes. The Current Limit Switch may be programmed to switch off in a selected timeslot within the shutdown sequence. If the Limit Switch is not allocated to one of the 14 shutdown timeslots, it will be disabled when the WM8352 enters the OFF state. The Current Limit Switch behaviour in Hibernate mode is controlled by the LS_HIB_MODE bit. ADDRESS BIT LABEL DEFAULT DESCRIPTION R13 (0Dh) 15 LS_ENA 0 Limit Switch enable 0 = disabled 1 = enabled Note: internal conditions may prevent the converter from actually switching on - see DCDC/LDO Status register for actual converter status. R176 (B0h) DC-DC / LDO requested 15 Note: LS_ENA can be accessed through R13 or through R176. Reading from or writing to either register location has the same effect. R199 (C7h) Limit switch control 13:10 LS_ENSLOT [3:0] 0000 Time slot for Limit Switch start-up 0000 = Disabled (do not start up) 0001 = Start-up in time slot 1 … (total 14 slots available) 1110 = Start-up in time slot 14 1111 = Start-up on entering ACTIVE 9:6 LS_SDSLOT [3:0] 0000 Time slot for Limit Switch shutdown. 0000 = Shut down on entering OFF 0001 = Shutdown in time slot 1 …. (total 14 slots available) 1110 = Shutdown in time slot 14 1111 = Shut down on entering OFF 4 LS_HIB_MO DE 0 Limit switch hibernate mode setting 0 = disabled 1 = leave setting as in Active mode Table 91 Enabling and Disabling the Current Limit Switch |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |