| Electronic Components Datasheet Search |
|
AD549 Datasheet(PDF) 12 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD549 Datasheet(HTML) 12 Page - Analog Devices |
|
12 / 12 page ![]() AD549 REV. A –12– The pH probe output is ideally zero volts at a pH of 7 indepen- dent of temperature. The slope of the probe’s transfer function, though predictable, is temperature dependent (–54.2 mV/pH at 0 and –74.04 mV/pH at 100 °C). By using an AD590 tempera- ture sensor and an AD535 analog divider, an accurate tempera- ture compensation network can be added to the basic pH probe amplifier. The table in Figure 47 shows voltages at various points and illustrates the compensation. The AD549 is set for a nonin- verting gain of 13.51. The output of the AD590 circuitry (point C) will be equal to 10 V at 100 °C and decrease by 26.8 mV/°C. The output of the AD535 analog divider (point D) will be a temperature compensated output voltage centered at zero volts for a pH of 7, and having a transfer function of –1.00 V/pH unit. The output range spans from –7.00 V (pH = 14) to +7.00 V (pH = 0). PROBE A B C D TEMP (PROBE OUTPUT) (A 13.51) (590 OUTPUT) (10 B/C) 0 54.20 mV 0.732 V 7.32 V 1.00 V 25 C 59.16 mV 0.799 V 7.99 V 1.00 V 37 C 61.54 mV 0.831 V 8.31 V 1.00 V 60 C 66.10 mV 0.893 V 8.93 V 1.00 V 100 C 74.04 mV 1.000 V 10.00 V 1.00 V Figure 47. Table Illustrating Temperature Compensation TEMPERATURE COMPENSATED pH PROBE AMPLIFIER A pH probe can be modeled as a mV-level voltage source with a series source resistance dependent upon the electrode’s compo- sition and configuration. The glass bulb resistance of a typical pH electrode pair falls between 10 6 and 109 Ω. It is therefore important to select an amplifier with low enough input currents such that the voltage drop produced by the amplifier’s input bias current and the electrode resistance does not become an appreciable percentage of a pH unit. The circuit in Figure 46 illustrates the use of the AD549 as a pH probe amplifier. As with other electrometer applications, the use of guarding, shielding, Teflon standoffs, etc., is a must in order to capitalize on the AD549’s low input current. If an AD549L (60 fA max input current) is used, the error contrib- uted by input current will be held below 60 µV for pH electrode source impedances up to 109 Ω. Input offset voltage (which can be trimmed) will be below 0.5 mV. Figure 46. Temperature Compensated pH Probe Amplifier OUTLINE DIMENSIONS Dimensions shown in inches and (mm). TO-99 (H) Package 0.045 (1.1) 0.020 (0.51) 0.034 (0.86) 0.028 (0.41) 1 3 5 0.2 (5.1) TYP 2 4 6 7 8 45° EQUALLY SPACED BOTTOM VIEW SEATING PLANE 0.019 (0.48) 0.016 (0.41) 0.335 (8.50) 0.305 (7.75) 0.370 (9.40) 0.335 (8.50) 0.500 (12.70) MIN 0.040 (1.0) MAX 0.185 (4.70) 0.165 (4.19) 8 LEADS DIA INSULATION 0.05 (1.27) MAX REFFERENCE PLANE |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |