Back Button GMS36 Datasheet HTML 55Page - Hynix Semiconductor GMS36 Datasheet HTML 56Page - Hynix Semiconductor GMS36 Datasheet HTML 57Page - Hynix Semiconductor GMS36 Datasheet HTML 58Page - Hynix Semiconductor GMS36 Datasheet HTML 59Page - Hynix Semiconductor GMS36 Datasheet HTML 60Page - Hynix Semiconductor GMS36 Datasheet HTML 61Page - Hynix Semiconductor GMS36 Datasheet HTML 62Page - Hynix Semiconductor GMS36 Datasheet HTML 63Page - Hynix Semiconductor Next Button
Zoom Inzoom in Zoom Outzoom out
 59 / 109 page
background image
5-14
(29) ALEM
Naming :
Accumulator Less Equal Memory
Status :
Carry to status
Format :
é
Function :
A
õ M(X,Y)
ST
à 1 (when A õ M(X,Y))
ST
à 0 (when A > M(X,Y))
<Comment>
Data of the accumulator is, through a complemental addition,
subtracted from data in the memory location addressed by the
X and Y-register. Carry data obtained is transferred to the
status. When the status is
Ì1Ì, it indicates that the data of
the accumulator is less than or equal to the data of the
memory word. Neither of those data is not changed.
(30) ALEI
Naming :
Accumulator Less Equal Immediate
Status :
Carry to status
Format :
ë
Function :
A
õ iST à 1 (when A õ i)
ST
à 0 (when A > i)
<Purpose>
Data of the accumulator and the constant are arithmetically
compared.
<Comment>
Data of the accumulator is, through a complemental addition,
subtracted from the constant that exists in 4bit operand. Carry
data obtained is transferred to the status. The status is set
when the accumulator value is less than or equal to the
constant. Data of the accumulator is left unchanged.
(31) MNEZ
Naming :
Memory Not Equal Zero
Status :
Comparison results to status
Format :
é
Function :
M(X,Y)
ó 0
ST
à 1(when M(X,Y) ó 0)
ST
à 0 (when M(X,Y) = 0)
<Purpose>
A memory word is compared with zero.
<Comment>
Data in the memory addressed by the X and Y-register is
logically compared with zero. Comparison data is thransferred
to the status. Unless it is zero, the status is set.
Chapter 5. INSTRUCTION



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com