Back Button UM0097 Datasheet HTML 40Page - STMicroelectronics UM0097 Datasheet HTML 41Page - STMicroelectronics UM0097 Datasheet HTML 42Page - STMicroelectronics UM0097 Datasheet HTML 43Page - STMicroelectronics UM0097 Datasheet HTML 44Page - STMicroelectronics UM0097 Datasheet HTML 45Page - STMicroelectronics UM0097 Datasheet HTML 46Page - STMicroelectronics UM0097 Datasheet HTML 47Page - STMicroelectronics UM0097 Datasheet HTML 48Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 44 / 229 page
background image
Peripheral firmware overview
UM0097
44/229
RCCU_FlagStatus
Example:
This example illustrates how to check if the PLL1 is locked.
{
...
while (RCCU_FlagStatus (RCCU_PLL1_LOCK_IT) == RESET);
...
}
RCCU_FlagClear
Example:
This example illustrates how to clear PLL1 lock pending interrupt flag.
{
...
RCCU_FlagClear (
RCCU_PLL1_LOCK_I);
...
}
Function Name
RCCU_FlagStatus
Function Prototype
FlagStatus RCCU_FlagStatus(RCCU_Flags RCCU_flag);
Behavior Description
Checks whether the specified interrupt is enabled or disabled.
Input Parameter
RCCU_flag: the flag to see its status. Refer to RCCU flags on page 34
for more details on the allowed values of this parameter.
Output Parameter
None
Return Value
The specified interrupt status.
– SET: The specified flag is set.
– RESET: The specified flag is reset
Required preconditions
None
Called Functions
None
Function Name
RCCU_FlagClear
Function Prototype
void RCCU_FlagClear (RCCU_Flags RCCU_flag);
Behavior Description
This routine is used to clear the specified interrupt flag in the RCCU
registers passed in parameter.
Input Parameter
RCCU_flag: Specifies the flag to clear. Refer to RCCU flags on page 34
for more details on the allowed values of this parameter.
Output Parameter
None
Return Value
None
Required preconditions
None
Called Functions
None



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com