| Electronic Components Datasheet Search |
|
ACT8941A Datasheet(PDF) 14 Page - Active-Semi, Inc |
|
|
|||||||||||||||||||||||||||||
ACT8941A Datasheet(HTML) 14 Page - Active-Semi, Inc |
|
14 / 42 page ![]() ACT8941A Rev 0, 12-Mar-13 - 14 - www.active-semi.com ActivePMU TM and ActivePathTM are trademarks of Active-Semi. I2CTM is a trademark of NXP. Copyright © 2013 Active-Semi, Inc. Innovative PowerTM Active-Semi Proprietary―For Authorized Recipients and Customers REGISTER AND BIT DESCRIPTIONS CONT’D OUTPUT ADDRESS BIT NAME ACCESS DESCRIPTION APCH 0x78 [0] CHGDAT1 R Charge State Machine Status. Value is 1 indicates the charger state machine is in EOC state, value is 0 indicates the charger state machine is in other states. APCH 0x79 [7] TIMRTOT R/W Total Charge Time-out Interrupt Control. Set both this bit and TIMRSTAT[ ] to 1 to generate an interrupt when a total charge time-out occurs. See the Charge Safety Timers section for more information. APCH 0x79 [6] TEMPIN R/W Battery Temperature Interrupt Control. Set both this bit and TEMPSTAT[ ] to 1 to generate an interrupt when the battery temperature goes into the valid range. See the Battery Temperature Monitoring section for more information. APCH 0x79 [5] INCON R/W Input Voltage Interrupt Control. Set both this bit and INSTAT[ ] to 1 to generate an interrupt when CHGIN input voltage goes into the valid range. See the Charge Current Programming section for more information. APCH 0x79 [4] CHGEOCIN R/W Charge State Interrupt Control. Set both this bit and CHGSTAT[ ] to 1 to generate an interrupt when the state machine goes into the EOC state. See the State Machine Interrupts section for more information. APCH 0x79 [3] TIMRPRE R/W PRECHARGE Time-out Interrupt Control. Set both this bit and TIMRSTAT[ ] to 1 to generate an interrupt when a PRECHARGE time-out occurs. See the Charge Safety Timers section for more information. APCH 0x79 [2] TEMPOUT R/W Battery Temperature Interrupt Control. Set both this bit and TEMPSTAT[ ] to 1 to generate an interrupt when the battery temperature goes out of the valid range. See the Battery Temperature Monitoring section for more information. APCH 0x79 [1] INDIS R/W Input Voltage Interrupt Control. Set both this bit and INSTAT[ ] to 1 to generate an interrupt when CHGIN input voltage goes out of the valid range. See the Charge Current Programming section for more information. APCH 0x79 [0] CHGEOCOUT R/W Charge State Interrupt Control. Set both this bit and CHGSTAT[ ] to 1 to generate an interrupt when the state machines jumps out of the EOC state. See the State Machine Interrupts section for more information. APCH 0x7A [7:6] - R Reserved. APCH 0x7A [5:4] CSTATE R Charge State. Values indicate the current charging state. See the State Machine Interrupts section for more information. APCH 0x7A [3:2] - R Reserved. APCH 0x7A [1] ACINSTAT R ACIN Status. Indicates the state of the ACIN input, typically in order to identify the type of input supply connected. Value is 1 when ACIN is above the 1.2V precision threshold, value is 0 when ACIN is below this threshold. APCH 0x7A [0] - R Reserved. APCH 0x78 [1] INDAT R Input Voltage Status. Value is 1 when a valid input at CHGIN is present. Value is 0 when a valid input at CHGIN is not present. APCH 0x78 [2] TEMPDAT1 R Temperature Status. Value is 0 when battery temperature is outside of valid range. Value is 1 when battery temperature is inside of valid range. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |