73 / 100 page ![]() CC1100 SWRS038D Page 73 of 92 0x16: MCSM2 – Main Radio Control State Machine Configuration Bit Field Name Reset R/W Description 7:5 Reserved R0 Reserved 4 RX_TIME_RSSI 0 R/W Direct RX termination based on RSSI measurement (carrier sense). For ASK/OOK modulation, RX times out if there is no carrier sense in the first 8 symbol periods. 3 RX_TIME_QUAL 0 R/W When the RX_TIME timer expires, the chip checks if sync word is found when RX_TIME_QUAL=0, or either sync word is found or PQI is set when RX_TIME_QUAL=1. RX_TIME[2:0] 7 (111) R/W Timeout for sync word search in RX for both WOR mode and normal RX operation. The timeout is relative to the programmed EVENT0 timeout. 2:0 The RX timeout in µs is given by EVENT0·C(RX_TIME, WOR_RES) ·26/X, where C is given by the table below and X is the crystal oscillator frequency in MHz: Setting WOR_RES = 0 WOR_RES = 1 WOR_RES = 2 WOR_RES = 3 0 (000) 3.6058 18.0288 32.4519 46.8750 1 (001) 1.8029 9.0144 16.2260 23.4375 2 (010) 0.9014 4.5072 8.1130 11.7188 3 (011) 0.4507 2.2536 4.0565 5.8594 4 (100) 0.2254 1.1268 2.0282 2.9297 5 (101) 0.1127 0.5634 1.0141 1.4648 6 (110) 0.0563 0.2817 0.5071 0.7324 7 (111) Until end of packet As an example, EVENT0=34666, WOR_RES=0 and RX_TIME=6 corresponds to 1.96 ms RX timeout, 1 s polling interval and 0.195% duty cycle. Note that WOR_RES should be 0 or 1 when using WOR because using WOR_RES > 1 will give a very low duty cycle. In applications where WOR is not used all settings of WOR_RES can be used. The duty cycle using WOR is approximated by: Setting WOR_RES=0 WOR_RES=1 0 (000) 12.50% 1.95% 1 (001) 6.250% 9765ppm 2 (010) 3.125% 4883ppm 3 (011) 1.563% 2441ppm 4 (100) 0.781% NA 5 (101) 0.391% NA 6 (110) 0.195% NA 7 (111) NA Note that the RC oscillator must be enabled in order to use setting 0-6, because the timeout counts RC oscillator periods. WOR mode does not need to be enabled. The timeout counter resolution is limited: With RX_TIME=0, the timeout count is given by the 13 MSBs of EVENT0, decreasing to the 7MSBs of EVENT0 with RX_TIME=6. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |