52 / 57 page ![]() M30LW128D 52/57 Figure 25. Protection Register Program Flowchart and Pseudo Code Note: 1. PR = Protection Register 2. The Read Status Register command must be issued to the same address as the Protection Register Program command. Write PR Add, PR Data(1) AI06159b YES NO b7 = 1 Start Write C0h Write FFh Read Status Register(2) PR Program Sucessful b4 = 1 VPEN Invalid Error Protection Register Program Error Protection Register Lock Error YES YES YES NO NO NO Protection Register Program Command – write C0h – write Protection Register Address, Protection Register Data do: – read status register while b7 = 1 Read Memory Array Command: – write FFh If b4 = 1 Protection Register Program Error b3 = 1 If b3 = 1 VPEN Invalid Error b1 = 1 If b1 = 1 Protection Register Lock Error |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|