4 / 27 page ![]() CP10.481 CP-Series 48V, 5.4A, SINGLE PHASE INPUT 3. AC-INPUT AC input nom. AC 100-240V suitable for TN-, TT- and IT mains networks AC input range min. 90-264Vac continuous operation min. 85-90Vac allowed up to +60°C amb. temperature and max. 240W allowed up to +55°C amb. temperature and max. 259W allowed up to +45°C amb. temperature and max. 288W min. 264-300Vac < 500ms Allowed voltage L or N to earth max. 300Vac continuous, IEC 62103 Input frequency nom. 50–60Hz ±6% Turn-on voltage typ. 80Vac steady-state value, see Fig. 3-1 typ. 55Vac dynamic value (250ms) Shut-down voltage typ. 70Vac steady-state value, see Fig. 3-1 External input protection See recommendations in chapter 23.3. AC 100V AC 120V AC 230V Input current typ. 2.82A 2.32A 1.20A at 48V, 5.4A, see Fig. 3-3 Power factor*) typ. 0.99 0.99 0.98 at 48V, 5.4A, see Fig. 3-4 Crest factor**) typ. 1.5 1.5 1.65 at 48V, 5.4A Start-up delay typ. 300ms 290ms 240ms see Fig. 3-2 Rise time typ. 63ms 63ms 63ms at 48V, 5.4A const. current load, 0mF load capacitance, see Fig. 3-2 typ. 210ms 210ms 210ms at 48V, 5.4A const. current load, 5mF load capacitance,, see Fig. 3-2 Turn-on overshoot max. 200mV 200mV 200mV see Fig. 3-2 External input protection See recommendations in chapter 23.3. *) The power factor is the ratio of the true (or real) power to the apparent power in an AC circuit. **) The crest factor is the mathematical ratio of the peak value to RMS value of the input current waveform. Fig. 3-1 Input voltage range Fig. 3-2 Turn-on behavior, definitions 90V Rated input range max. 500ms V IN P OUT 4/27 300Vac 264V Start-up delay Rise Time - 5% Output Voltage Input Voltage Fig. 3-3 Input current vs. output current at 48V output voltage Fig. 3-4 Power factor vs. output current at 48V output voltage 6A 0.5 1 1.5 2 2.5 3 3.5 4 4.5 0 0.5 1.0 1.5 2.0 2.5 3A Input Current, typ. 55.5 a) 100Vac b) 120Vac c) 230Vac Output Current (a) (b) (c) Power Factor, typ. 0.5 1 1.5 2 2.5 3 3.5 4 4.5 6A 0.75 0.8 0.85 0.9 0.95 1.0 55.5 Output Current (a) 100Vac, (b) 120Vac, (c) 230Vac (a) (b) (c) Feb. 2016 / Rev. 1.1 DS-CP10.481-EN All parameters are specified at 48V, 5.4A, 230Vac, 50Hz, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |