13 / 21 page ![]() 1.0 Functional Description (Continued) 1.12 Fault Queue In order to suppress erroneous ALERT or T_CRIT triggering the LM86 incorporates a Fault Queue. The Fault Queue acts to insure a remote temperature measurement is genuinely beyond a HIGH, LOW or T_CRIT setpoint by not triggering until three consecutive out of limit measurements have been made, see Figure 10. The fault queue defaults off upon power-up and may be activated by setting bit D0 in the Configuration register (09h) to “1”. 1.13 One-Shot Register The One-Shot register is used to initiate a single conversion and comparison cycle when the device is in standby mode, after which the device returns to standby. This is not a data register and it is the write operation that causes the one-shot conversion. The data written to this address is irrelevant and is not stored. A zero will always be read from this register. 2.0 LM86 REGISTERS 2.1 COMMAND REGISTER Selects which registers will be read from or written to. Data for this register should be transmitted during the Command Byte of the SMBus write communication. P7 P6 P5 P4 P3 P2 P1 P0 Command Select P0-P7: Command Select Command Select Address Power On Default State Register Name Register Function Read Address <P7:P0> hex Write Address <P7:P0> hex <D7:D0> binary <D7:D0> decimal 00h NA 0000 0000 0 LT Local Temperature 01h NA 0000 0000 0 RTHB Remote Temperature High Byte 02h NA 0000 0000 0 SR Status Register 03h 09h 0000 0000 0 C Configuration 04h 0Ah 0000 1000 8 (16 conv./sec) CR Conversion Rate 05h 0Bh 0100 0110 70 LHS Local HIGH Setpoint 06h 0Ch 0000 0000 0 LLS Local LOW Setpoint 07h 0Dh 0100 0110 70 RHSHB Remote HIGH Setpoint High Byte 08h 0Eh 0000 0000 0 RLSHB Remote LOW Setpoint High Byte NA 0Fh One Shot Writing to this register will initiate a one shot conversion 10h NA 0000 0000 0 RTLB Remote Temperature Low Byte 10130330 FIGURE 10. Fault Queue Temperature Response Diagram www.national.com 13 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |