| Electronic Components Datasheet Search |
|
L9396 Datasheet(PDF) 58 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L9396 Datasheet(HTML) 58 Page - STMicroelectronics |
|
58 / 109 page ![]() Remote sensor interface L9396 58/109 DS12539 Rev 6 5.2 Tracking regulation RSUH0 and RSUH1 output pins can be configured as independent tracking regulators; this is the default configuration at start-up. Each regulator tracks the voltage reference given by the VCC (default) or VCC5 rail, depending on the user selection via SPI command. The 2 channels can be activated or deactivated independently (default state is off). Over/under voltage and over current monitoring are applied to RSU0/1 channels when in tracking regulator configuration and result bits are available via SPI. 5.3 Remote sensor interface fault protection Each output is short circuit protected by an independent current limit and a thermal detection circuit. Current limit and overcurrent detection are present for both RSUHx and RSULx and they are independent of RSUHx and RSULx. In case RSUHx overcurrent is detected the output stage is disabled after filter time while in case of RSULx overcurrent it's not disabled. In any case if the thermal protection (shared between RSUH and RSUL) is triggered the output stage is disabled. In case the thermal warning level would not be reached, the current limitation circuitry will prevent damages on the channel, while operating the output. This fault condition does not interfere with the normal operation of the IC or with the operation of the other channels. All RSUHx(x=0,1,2,3) are independently protected against a short to battery condition. Short to battery protection disconnects the channel from its supply rail to guarantee that no adverse condition occurs within the IC. The channel in short to battery is not shutdown by this condition. Other channels are not affected in case of short of one output pin. The sensor interface of RSULx(x=0,1,2,3) also offers open condition (only in ON state) and short to ground detection (only in OFF state). The channel in this condition is not shutdown. If there is open circuit for RSUHx, it will be detected by open detection of corresponding RSULx if the sensor is still connected to RSULx. The short to ground detection is implemented with a pull-up current (IRSUL_PU) and a voltage comparator (VSTGTH) on RSULx (x=0,1,2,3). Requirement is that external short to Table 39. RSU_STATUS register ADDR NAME TYPE BITS = 8 0001010 RSU_STATUS R LS Over Current and Short to ground Status Table 40. RSU_STATUS register bit description Data Field Description Reset Value TYPE Bit 7:4 LS OVER CURRENT channels 3:0. (Active if the wss LS are ON) 0 => NO FAULT 1 => FAULT 0 SSM_RESET LBIST Bit 3:0 LS Short To Ground channels 3:0. (Active if the wss LS are OFF) 0 => NO FAULT 1 => FAULT 0 SSM_RESET LBIST |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |