32 / 96 page ![]() PAC194X DS20006543A-page 32 2021 Microchip Technology Inc. 5.16.4 ALERT FUNCTIONALITY – VOLTAGE, CURRENT AND POWER The ALERT functionality enables the user to capture voltage and current events that exceed programmable limits, for one or more samples. The ALERT function may be monitored on a digital output pin by configuring one of the ALERT pins to correspond to a specific ALERT or to multiple ALERT signals using Register 7-21 or Register 7-22. The ALERT status may also be monitored over the I2C/SMBus by reading Register 7-20. ALERT can be triggered by a variety of triggers; VBUS overvoltage or undervoltage (OV or UV), VSENSE over- current or undercurrent (OC or UC), overpower (OP), conversion cycle complete or accumulator/accumula- tor count hitting a limit for fullness or overflowing. The OV, UV, OC, UC and/or OP limits must be enabled for any of the channels that will be using them, by set- ting a bit in Register 7-34. These limits are specified with two’s complement values independent of whether Unipolar/Bipolar Or Unidirectional/Bidirectional modes are set for VBUS and VSENSE measurements. Only ALERT conditions that are enabled here are capable of triggering any ALERT. A REFRESH (or REFRESH_V/G) command is required after writing to Register 7-34 for the ALERTs to be enabled. 5.16.5 ALERT THRESHOLD LIMITS Each channel has programmable 16-bit limits for overcurrent, undercurrent, overvoltage and undervoltage. The overpower limit is a 24-bit number. The thresholds for these ALERTs are set in Register 7-24, Register 7-25, Register 7-26, Register 7-27 and Register 7-28. 5.16.6 SAMPLES OVER LIMIT TO TRIGGER ALERT The user can also program how many samples must exceed the threshold to trigger the ALERT pin (over limit samples). The default value for over limit samples is 1 (up to a maximum 16 samples), which means the ALERT will be triggered on the first sample that exceeds the threshold. For OC, OP and OV, exceed- ing the threshold means a sample that is of larger value than the programmed limit. For UC and UV, exceeding the threshold means a sample that is of smaller value than the programmed limit. The OP limit differs slightly from the other limits in that it is always magnitude based. Thus a more positive value or more negative value will trigger an OP alert. The user can program how many samples over the threshold are required to trigger the ALERT for each of these parameters in Register 7-28, Register 7-29, Register 7-31, Register 7-32 and Register 7-33. 5.16.7 ACCUMULATOR-BASED ALERTS The ALERT function can also be programmed to trigger when the accumulator or accumulator count for any channel is filled to a specified amount. This amount can be programmed from 15/16 full through 7/8, 3/4 or completely full. This enables the user to maximize the accumulation time instead of simply planning for the worst case. The limits for each channel are specified in Register 7-23. When the ALERT is tripped, the user can interrogate Register 7-20 to determine which conditional limit, which channel(s) or if the accumulator/accumulator count condition triggered the ALERT. The ALERT con- dition is cleared when these ALERT cause registers are read, specifically when the register that caused for the specific ALERT cause is read. Register 7-20 is updated immediately on an ALERT condition, it does not require a REFRESH command. When the ALERT function is tripped by accumulator overflow, it remains asserted until a REFRESH com- mand is received. REFRESH_G will also clear the ALERT bit and the ALERT function, but REFRESH_V will not. 5.16.8 ALERT CLEARING AND PERSISTENT FAULT CONDITIONS If the over/undervoltage, over/undercurrent or overpower conditions that tripped the ALERT or accu- mulator full conditions are still present after the ALERT cause register is read (which clears all the bits in that register and resets the ALERT function), the ALERT function will reassert, if the next converted sample that detects the limit is exceeded. Register 7-20 is cleared when it is read. If the ALERT condition is still present after the next conversion cycle is complete, the ALERT is reasserted. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |