| Electronic Components Datasheet Search |
|
F204AC-63/0.1 Datasheet(PDF) 19 Page - ABB |
|
|
|||||||||||||||||||||||||||||
F204AC-63/0.1 Datasheet(HTML) 19 Page - ABB |
|
19 / 62 page ![]() Surge Pr otective Devices Low Voltage Products & Systems 16.17 ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A 16 16 Product selection OVR DIN rail SPD One pole Catalog number Service voltage 1) Max. discharge current (Imax, 8/20µs, kA) Aux. contact - remote monitoring Replacement cartridge OVRT215150PU 120V Single Phase, 240/120V Split Phase, 208/120V Wye 15 No OVRT215150CU OVRT215320PU 240/120V HLD, 240V Delta, 240V Single Phase, 277V Single Phase, 480/240V Split Phase, 480/277V Wye 15 No OVRT215320CU OVRT240150PU 120V Single Phase, 240/120V Split Phase, 208/120V Wye 40 No OVRT240150CU OVRT240150PTSU 120V Single Phase, 240/120V Split Phase, 208/120V Wye 40 Yes OVRT240150CU OVRT240320PU 240/120V HLD, 240V Delta, 240V Single Phase, 277V Single Phase, 480/240V Split Phase, 480/277V Wye 40 No OVRT240320CU OVRT240320PTSU 240/120V HLD, 240V Delta, 240V Single Phase, 277V Single Phase, 480/240V Split Phase, 480/277V Wye 40 Yes OVRT240320CU OVRT240440PTSU 600/347V Wye 40 Yes OVRT240440CU OVRT240550PTSU 480V Delta 40 Yes OVRT240550CU OVRT240660PTSU 600V Delta 40 Yes OVRT240660CU 1) May require multiple SPDs Two pole Catalog number Service voltage 1) Max. discharge current (Imax, 8/20µs, kA) Aux. contact - remote monitoring Replacement cartridge 2) OVRT22L15150PU 120V Single phase, 240/120V Split phase, 208/120V Wye 15 No OVRT215150CU OVRT22L15320PU 240/120V HLD, 240V Delta, 240V Single phase, 277V Single phase, 480/240V Split phase, 480/277V Wye 15 No OVRT215320CU OVRT22L40150PTSU 120V Single phase, 240/120V Split phase, 208/120V Wye 40 Yes OVRT240150CU OVRT22L40320PTSU 240/120V HLD, 240V Delta, 240V Single phase, 277V Single phase, 480/240V Split phase, 480/277V Wye 40 Yes OVRT240320CU 1) May require multiple SPDs 2) May require up to two replacement cartridges Three pole Catalog number Service voltage 1) Max. discharge current (Imax, 8/20µs, kA) Aux. contact - remote monitoring Replacement cartridge 2) OVRT23L15150PU 240/120V Split phase, 208/120V Wye 15 No OVRT215150CU OVRT23L15320PU 240/120V HLD, 240V Delta, 480/240V Split phase, 480/277V Wye 15 No OVRT215320CU OVRT23L40150PTSU 240/120V Split phase, 208/120V Wye 40 Yes OVRT240150CU OVRT23L40320PTSU 240/120V HLD, 240V Delta, 480/240V Split phase, 480/277V Wye 40 Yes OVRT240320CU OVRT23L40440PTSU 240V Delta, 480/240V Split phase, 600/347V Wye 40 Yes OVRT240440CU OVRT23L40550PTSU 480V Delta 40 Yes OVRT240550CU 1) May require multiple SPDs 2) May require up to three replacement cartridges Consult the Service Voltage and Location table on page 16.16 for proper SPD selection. The following tables also present information on service voltage compatibility. Please note that multiple SPDs may be required depending on service voltage. Contact ABB Technical Support with any questions. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |