89 / 109 page ![]() Common to F3SG-SR and F3SG-PG 89 Manual Reset Mode with Reset Switch Connector [Wiring Example] Note: 1. When using the Reset Switch Connector (F39-GCNY3), the following functions are not available. • External Device Monitoring (EDM) 2. For the functional earth connection, refer to page 83. F3SG-SRA Available F3SG-PGA-A/-L Available F3SG-SRB Available F3SG-PGA-C Available *9 S2 S1 24 VDC 24 VDC F39-JGR3K-L F39-JG A-L F39-GCNY3 F39-JGR3K-D XS5F-D421 80-F F39-JG A-D IN1 IN2 L1 Wiring for NPN *1 Safety controller *3 *4 Timing chart Beam state: Unblocked Blocked Reset switch (S2) Test switch (S1) OSSD S1: Test switch S2: Lockout/interlock reset switch L1: Lamp *5 Innteligent Tap Needed *1. Reverse the polarity of the power supply when using in the NPN system. Select a PLC and a safety controller of PNP or NPN type according to the system of your application. *2. Connect the line to 0 V. *3. Refer to page 79 for more information. *4. The safety controller and the F3SG-SR/PG must share the power supply or be connected to the common terminal of the power supply. *5. This is the case for a PELV circuit. *6. Set the function with the DIP Switches on the Intelligent Tap or the SD Manager 3, restore the settings to the F3SG-SR/PG, and perform wiring according to the wiring diagram. *7. This wiring example shows light emission stop when connected to 24 VDC with PNP setting, and light emission stop when connected to 0 VDC with NPN setting. If TEST switch is not needed, refer to the User's Manual (Man. No. Z405). *8. The F3SG-PGA-C does not support the external test function. *9. When wiring the emitter/receiver of the F3SG-PGA-C, follow the same wiring as for the receiver in the figure above. Wiring of the emitter side is not required. : Indicates a switch position. Function Setting DIP switch SD Manager 3 EDM EDM Disabled (factory default setting) [External device monitoring] : Disable Interlock *6 Manual Reset (Start/ Restart Interlock) [Start interlock] : Enable [Restart interlock] : Enable Operating Range Selection Long : Open the OPERATING RANGE SELECT INPUT line of the emitter or connect the line to 24 VDC. Non-Muting system Perform wiring according to the wiring diagram. N/A [Muting] : Disable *6 External Test used *8 Connect the TEST line of the emitter to 24V/0V of the emitter via a test switch (NO contact). *7 N/A [External test signal inversion] : Disable Optical Synchronization Open the COM(+) and COM(-) lines of the emitter. 4ON 5ON |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |