| Electronic Components Datasheet Search |
|
BME690 Datasheet(PDF) 21 Page - Bosch Sensortec GmbH |
|
|
|||||||||||||||||||||||||||||
BME690 Datasheet(HTML) 21 Page - Bosch Sensortec GmbH |
|
21 / 60 page ![]() Bosch Sensortec | BME690 - Datasheet 21 | 60 © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, Document number: BST-BME690-DS001-04 as well as in the event of applications for industrial property rights Figure 4: Sensor configuration flow in Parallel Mode Parallel Mode Select oversampling for T, P and H • Set osrs_x<2:0> Select IIR filter for temperature sensor • Set filter<2:0> Enable gas conversion • Set run_gas to 1 Select number of steps in heater profile • Set nb_conv <3:0> (from 1 to 10) Set heater-on time of each step • Calculate required wait time before each TPHG measurement and set gas_wait_shared<7:0> • Calculate number of TPHG repitions needed and set gas_wait_x<7:0> (up to 255) Set heater temperature of each step • Convert heater temperature to register code • Set res_heat_x<7:0> Set mode to parallel mode • Set mode<1:0> to 0b10 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |