| Electronic Components Datasheet Search |
|
BME690 Datasheet(PDF) 39 Page - Bosch Sensortec GmbH |
|
|
|||||||||||||||||||||||||||||
BME690 Datasheet(HTML) 39 Page - Bosch Sensortec GmbH |
|
39 / 60 page ![]() Bosch Sensortec | BME690 - Datasheet 39 | 60 © Bosch Sensortec GmbH 2025 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, Document number: BST-BME690-DS001-04 as well as in the event of applications for industrial property rights Gas control registers The sensor can have 10 programmable gas sensor heater steps. Each heater step consists of a target heater resistance corresponding to heater temperature, heater-on time and optionally an initial heater current. 5.3.4.1 Heater current - idac_heat_x BME690 contains a heater control block that will inject enough current into the heater resistance to achieve the requested heater temperature. There is a control loop which periodically measures heater resistance value and adapts the value of current injected from a DAC. The heater operation could be speeded up by setting an initial heater current for a target heater temperature by using register idac_heat_x<7:0>. This step is optional since the control loop will find the current after a few iterations anyway. The current injected to the heater in mA can be calculated by: (idac_heat_7_1 + 1) / 8, where idac_heat_7_1 is the decimal value stored in idac_heat<7:1> (unsigned, value from 0 to 127). Heater steps Register name Address Content Description 0...9 idac_heat_x x is from 0 to 9 0x50…0x59 idac_heat_x<7:0> x is from 0 to 9 idac_heat of particular heater set point 5.3.4.2 Target heater resistance - res_heat_x Target heater resistance is programmed by user through res_heat_x<7:0> registers. The definition of res_heat_x is given in Section 3.6.5. Heater step Register name Address Content Description 0...9 res_wait_x x is from 0 to 9 0x5A…0x63 res_heat_x<7:0> x is from 0 to 9 Decimal value that needs to be stored for achieving target heater resistance 5.3.4.3 Gas Sensor heater-on time in Forced mode - gas_wait_x Referring to Figure 2, the time between the beginning of the heat phase and the start of gas sensor resistance measurement depends on gas_wait_x setting as mentioned below. Heater step Register name Address Content Description 0...9 gas_wait_x x is from 0 to 9 0x64…0x6D gas_wait_x<5:0> x is from 0 to 9 64 timer values with 1 ms step sizes, all zeros means no wait 0...9 gas_wait_x x is from 0 to 9 0x64…0x6D gas_wait_x<7:6> x is from 0 to 9 Timer multiplication factor as shown in below table gas_wait_x<7:6> Gas sensor wait time multiplication factor 00 1 01 4 10 16 11 64 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |