| Electronic Components Datasheet Search |
|
ISO7641FC Datasheet(PDF) 21 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
ISO7641FC Datasheet(HTML) 21 Page - Texas Instruments |
|
21 / 37 page ![]() 21 ISO7631FM, ISO7631FC, ISO7641FC www.ti.com SLLSEC3F – SEPTEMBER 2012 – REVISED APRIL 2016 Product Folder Links: ISO7631FM ISO7631FC ISO7641FC Submit Documentation Feedback Copyright © 2012–2016, Texas Instruments Incorporated (1) Climatic Classification 40/125/21 (2) All pins on each side of the barrier tied together creating a two-terminal device. Table 1. DIN V VDE V 0884-10 (VDE V 0884-10):2006-12 Insulation Characteristics(1) PARAMETER TEST CONDITIONS SPECIFICATION UNIT VIORM Maximum working insulation voltage 1414 VPEAK VPR Input-to-output test voltage After Input/Output safety test subgroup 2/3, VPR = VIORM x 1.2, t = 10 s, Partial discharge < 5 pC 1697 VPEAK Method a, After environmental tests subgroup 1, VPR = VIORM x 1.6, t = 10 s, Partial Discharge < 5 pC 2262 Method b1, 100% Production test VPR = VIORM x 1.875, t = 1 s Partial discharge < 5 pC 2652 VIOTM Maximum transient overvoltage VTEST = VIOTM t = 60 sec (Qualification) t = 1 sec (100% Production) 4242 VPEAK RIO (2) Isolation resistance, Input to Output VIO = 500 V, TA = 25°C >1012 Ω VIO = 500 V, 100°C ≤ TA ≤ 125°C >1011 VIO = 500 V at TS = 150°C >109 CIO (2) Barrier capacitance, Input to Output VI = 0.4 sin (2πft), f = 1MHz 2 pF Pollution degree 2 Table 2. IEC 60664-1 Ratings Table PARAMETER TEST CONDITIONS SPECIFICATION Material Group II Installation classification / Overvoltage category for basic insulation Rated mains voltage ≤ 300 VRMS I–IV Rated mains voltage ≤ 600 VRMS I–III Rated mains voltage ≤ 1000 VRMS I–II (1) Production tested ≥ 3000 VRMS for 1 second in accordance with UL 1577. Table 3. Regulatory Information VDE TUV CSA UL CQC Certified according to DIN V VDE V 0884-10 (VDE V 0884-10):2006- 12 and DIN EN 61010- 1 (VDE 0411-1):2011- 07 Certified according to EN/UL/CSA 60950-1 and 61010- 1 Approved under CSA Component Acceptance Notice 5A, IEC 60950-1 and IEC 61010-1 Recognized under 1577 Component Recognition Program Certified according to GB4943.1-2011 Basic Insulation Maximum Transient Overvoltage, 4242 VPK Maximum Working Voltage, 1414 VPK 3000 VRMS Reinforced Insulation, 400 VRMS maximum working voltage 3000 VRMS Basic Insulation, 600 VRMS maximum working voltage 3000 VRMS Isolation Rating Single Protection, 2500 VRMS (1) Reinforced Insulation, Altitude ≤ 5000 m, Tropical Climate, 250 VRMS Maximum Working Voltage Certificate number: 40016131 Certificate number: U8V 13 09 77311 010 Master contract number: 220991 File number: E181974 Certificate number: CQC14001109542 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |