| Electronic Components Datasheet Search |
|
AFPG804 Datasheet(PDF) 3 Page - Panasonic Semiconductor |
|
|
|||||||||||||||||||||||||||||
AFPG804 Datasheet(HTML) 3 Page - Panasonic Semiconductor |
|
3 / 9 page ![]() KW1M/KW1M-H Eco-POWER METER (AKW1) MEASUREMENT ITEMS *1. For AKW1110, AKW1121 only *2. Eco-POWER METER is designed chiefly for managing energy saving. It is not intended to be used for billing. SPECIFICATIONS Main unit *1. Analog input terminals: No.3 to No.6 (for AKW1111), No.4 to No.6 (for AKW1110 and AKW1121) Pulse input terminals: No.12 and No.13 (for AKW1111) No Connection terminal (N.C.) is internally connected to the analog input circuit. Item Unit Data displayed range Instantaneous electric power (Active) kW 0.00 to 9999.99 Integrated electric power (Active) kWh/MWh 0.00 to 9999.99kWh 0.00 to 9999999.99kWh (When 9-digit display) Current R current A 0.0 to 6000.0 S current*1 A 0.0 to 6000.0 T current A 0.0 to 6000.0 Voltage R (RS) voltage V 0.0 to 9999.9 S (RT) voltage*1 V 0.0 to 9999.9 T (TS) voltage V 0.0 to 9999.9 Electricity charge*2 — 0.00 to 999999 Converted CO2 value kg-CO2 0.00 to 999999 Power factor*1 — 0.0 to 1.00 (Identify leading phase “–” or lagging phase) (Only in range of phase angle θ = –90° to +90°) Frequency*1 Hz 47.5 to 63.0 Hour meter ON time h (Hour) 0.0 to 99999.9 OFF time h (Hour) 0.0 to 99999.9 Pulse counter*1 —0 to 999999 Item Specifications Rated operating voltage 100 to 240V AC Rated frequency 50/60Hz common Rated power consumption AKW1110: 6 VA (240V AC at 25 °C) / AKW1111, AKW1121: 8 VA (240V AC at 25°C) Allowable operating voltage range 85 to 264V AC (85% to 110% of rated operating voltage) Allowable momentary power-off time 10ms Ambient temperature –10 to +50 °C (–25°C to +70°C at storage) Ambient humidity 30 to 85%RH (at 20 °C non-condensing) Breakdown voltage (initial) Between the isolated circuits: 2000V for 1min • Outer edge (case) – all terminals • Insulated circuit - Operating power supply terminals – Analog input terminals*1 - Operating power supply terminals – Pulse input terminals*1 - RS485 – All other terminals - Pulse output terminals – All other terminals Insulation resistance (initial) Between the isolated circuits: 100M Ω or more (measured with 500V DC) Vibration resistance 10 to 55Hz (1cycle/min) single amplitude: 0.375mm (1h on 3 axes) Shock resistance Min. 294m/s2 (5 times on 3 axes) Display method LCD with backlight Upper section: Green, 4-digit, 16-segment, Letter height: 6.5 mm Lower section: Amber, 6-digit, 7-segment, Letter height: 7.5 mm Power failure memory method EEP-ROM (more than 100,000 overwrite) Size 75 × 90 × 50 mm Weight AKW1110 and AKW1111: approx. 170g, AKW1121: approx. 180g (without battery) All Rights Reserved © C OPYRIGHT Panasonic Electric Works Co., Ltd. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |