AFPG804 Datasheet(PDF) 7 Page - Panasonic Semiconductor |
|
|
|||||||||||||||||||||||||||||
AFPG804 Datasheet(HTML) 7 Page - Panasonic Semiconductor |
|
7 / 9 page ![]() KW1M/KW1M-H Eco-POWER METER (AKW1) The input voltage to each terminal is as follows. (AKW1111) The input voltage to each terminal is as follows. (AKW1110 and AKW1121) Wiring diagrams • AKW1110 Measure load of 100 to 200VAC system When measuring a load with exceed rated input voltage The voltage transformer (VT) is required when you measure a load with exceed rated input voltage (220 V AC system). Use commercial VT, those secondary rating is 110 V. Terminal Phase and wire system Between terminals Input voltage AKW1111 Operating power supply Single-phase two-wire Q-W 100 to 240VAC (100-240V~) (Line voltage) Measured voltage input Single-phase two-wire E-R 0 to 440VAC (0-440V~) (Line voltage) Single-phase three-wire E-R-T 0 to 220VAC (0-220V~: 3W) (Phase voltage) Three-phase three-wire E-R-T 0 to 440VAC (0-440V 3~) (Line voltage) Three-phase four-wire E-R-T-Y 0 to 254VAC (0-254V 3N~) (Phase voltage) Terminal Phase and wire system Between terminals Input voltage AKW1110 AKW1121 Operating power supply Single-phase two-wire Q-W 100 to 240VAC (100-240V~) (Line voltage) Measured voltage input Single-phase two-wire R-T 0 to 220VAC (0-220V~) (Line voltage) 0 to 440VAC (0-440V~) (Line voltage) Single-phase three-wire R-T-Y 0 to 110VAC (0-110V~: 3W) (Phase voltage) 0 to 220VAC (0-220V~: 3W) (Phase voltage) Three-phase three-wire R-T-Y 0 to 220VAC (0-220V 3~) (Line voltage) 0 to 440VAC (0-440V 3~) (Line voltage) Three-phase four-wire R-T-Y-U —0 to 254VAC (0-254V 3N~) (Phase voltage) • AKW1121 Function Terminal No. Function Operating power supply L QI + RS485 N WO − N.C. EP E Measured voltage input P1 R{ + Pulse output P0 T} − P2 Yq + Pulse input P3 Uw − IOP{} E P1 P0 P2 P3 qw QWERTYU Operating power supply Measured voltage input RS485 Pulse output Pulse input Direction of CT L K CT1 RS485 Pulse output E – +– + P0 P1 N.C. *Do not connect to CT2 and CT3. CT1 *1 *1 *1 *1 *1 *Do not connect to CT3. CT1 CT2 • Single-phase two-wire system • Single-phase three-wire system/Three-phase three-wire system *One CT is required. *Two CTs are required. 7 6 5 4 3 2 1 14 13 12 11 10 9 8 0.1A 30VDC Operating power supply 100 to 240VAC 50/60Hz Measured voltage input 1 2 Load side Power supply side Direction of CT L K RS485 Pulse output E – +– + *2 *2 14 13 12 11 10 9 8 0.1A 30VDC P0 P2 P1 N.C. *2 *2 7 6 5 4 3 2 1 Operating power supply 100 to 240VAC 50/60Hz Measured voltage input CT1 CT2 1 2 3 R S T R N T Load side Power supply side *1. Do not wire to E, Y, U, q, w terminal. They are connected internal. *2. Do not wire to E, U, q, w terminal. They are connected internal. R VT T R R S T R N T 1 1 2 2 3 VT T Y Eco-POWER METER (Secondary side) • Single-phase two-wire system • Single-phase three-wire system/ Three-phase three-wire system (Primary side) Load side Load side Power supply side Power supply side Eco-POWER METER (Secondary side) (Primary side) *Grounding the secondary side of voltage transformer (VT) and current transformer (CT) is not necessary with low voltage circuit. All Rights Reserved © C OPYRIGHT Panasonic Electric Works Co., Ltd. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |