4 / 9 page ![]() KW1M/KW1M-H Eco-POWER METER (AKW1) Power input specifications Pulse input specifications (For AKW1111 and AKW1121) Pulse output (transistor output) specifications *We recommend the setting of minimum unit for pulse output for measurement shown as below. Output pulse: 4 pulse or less per 1sec. Calculation method: (Pulse output unit: value of PL-P) > (Max. measured power [kW]) / (3600 [s] × 4 [pulse/s]) Note 1: Count errors may occur if pulse output unit is set so that 4 or more pulses are output per 1 second. Note 2: The connected counter or PLC may cause count errors if the OFF time of the pulse output unit is short. Item Specifications AKW1110 AKW1111 and AKW1121 Phase and wire system Single-phase two-wire, Single-phase three-wire, Three-phase three-wire (common) Single-phase two-wire, Single-phase three-wire, Three- phase three-wire, Three-phase four-wire (common) Input voltage Rating Single-phase two-wire: 0 to 220V AC (Line voltage) Single-phase three-wire: 0 to 110V AC (Phase voltage) Three-phase three-wire: 0 to 220V AC (Line voltage) Single-phase two-wire: 0 to 440V AC (Line voltage) Single-phase three-wire: 0 to 220V AC (Phase voltage) Three-phase three-wire: 0 to 440V AC (Line voltage) Three-phase four-wire: 0 to 254V AC (Phase voltage) Allowable measurement voltage Up to 120% of rated input voltage Single-phase two-wire: 0 to 264V AC (Line voltage) Single-phase three-wire: 0 to 132V AC (Phase voltage) Three-phase three-wire: 0 to 264V AC (Line voltage) Single-phase two-wire: 0 to 528V AC (Line voltage) Single-phase three-wire: 0 to 264V AC (Phase voltage) Three-phase three-wire: 0 to 528V AC (Line voltage) Three-phase four-wire: 0 to 300V AC (Phase voltage) VT ratio 1.00 to 99.99 (Set with setting mode) *A Voltage transformer (VT) is required when measuring loads that exceed the rated input voltage (AKW1110 is 200 VAC and AKW1111 and AKW1121 are 440 VAC). (Please use a commercially available VT with rated secondary measurement voltage of 110 V.) Input current Primary side rating <In case using dedicated CT> 5 A/50 A/100 A/250 A/400 A (Select with setting mode) <In case using commercial CT with secondary side 5A> 1 to 4000 A (Set with setting mode) *Use a commercial CT with secondary side current of 5A when measure 400A or more. *Accuracy coverage: 10 to 100% of rated current of CT Special functions Cut-off current 1.0 to 50.0%F.S. (Select with setting mode) Cut-off voltage Within 5% of rated voltage (within voltage value sought by rated voltage × 0.05 × VT ratio) (fixed) Current threshold for hour meter 1.0 to 100.0%F.S. Accuracy (without error in CT and VT) Indication accuracy Instantaneous electric power Integrated electric power Voltage Current Electricity charge Calculated CO2 value ±2.5% F.S. +1 digit (at 20°C, rated input, rated frequency, power factor 1) *Accuracy coverage: 10 to 100% of rated current of CT Hour meter ±0.01%+1digit (at 20°C), Monthly accuracy: ±260 sec. (for your reference) (In case power on start or current energizing: ±0.01%+1s+1 digit, at 20°C) Temperature characteristics ±1.5% F.S. /10°C +1 digit (Range of –10 to 50°C for rated input, power factor 1) Frequency characteristics ±1.5% F.S. +1 digit (Frequency change±5% based on rated frequency, for rated input, power factor 1) Item Specifications Input mode Addition (Fixed) Max. counting speed 2kHz/30Hz (Select with setting mode) Pulse input Min. input signal width: 0.25ms (When 2kHz selected)/16.7ms (When 30Hz selected), ON : OFF ratio = 1 : 1 Input signal (at 20 °C) Contact/No contact (open collector) • Impedance when shorted: Max. 1k Ω • Residual voltage when shorted: Max. 2V • Impedance when open: Min. 100k Ω Output mode HOLD (Over count) Pre-scale setting Decimal point Setting possible up to 3 digits after decimal point Range 0.001 to 100.000 (Select with setting mode) Item Specifications Number of output point 1 point Insulation method Optical coupler Output type Open collector Output capacity 100mA 30V DC Pulse width Approx. 100ms ON state voltage drop 1.5V or less OFF state leakage current 100 µA or less Pulse output unit (Select with setting mode) AKW1110 0.001/0.01/0.1/1/10/100 kWh/Power alarm (AL-P)/Current alarm (AL-C) AKW1111 and AKW1121 0.001/0.01/0.1/1/10/100 kWh/Power alarm (AL-P)/Current alarm (AL-C)/Standby power alarm (AL-S)/ Counter (Cnt) All Rights Reserved © C OPYRIGHT Panasonic Electric Works Co., Ltd. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |