| Electronic Components Datasheet Search |
|
AFPG804 Datasheet(PDF) 8 Page - Panasonic Semiconductor |
|
|
|||||||||||||||||||||||||||||
AFPG804 Datasheet(HTML) 8 Page - Panasonic Semiconductor |
|
8 / 9 page ![]() KW1M/KW1M-H Eco-POWER METER (AKW1) • AKW1111 Measure load of 100 to 200 VAC and 400 VAC system When measuring a load with exceed rated input voltage The voltage transformer (VT) is required when you measure a load with exceed rated input voltage (440 V AC system). Use commercial VT, those secondary rating is 110 V. • AKW1121 Measure load of 100 to 200 VAC and 400 VAC system *Do not connect to CT2 and CT3. CT1 *Do not connect to CT3. CT1 CT2 CT3 CT1 CT2 Direction of CT L K RS485 Pulse output Pulse input • Single-phase two-wire system • Single-phase three-wire system/Three-phase three-wire system *One CT is required. *Two CTs are required. CT1 E – +– – ++ P0 P1 *1 *1 6 5 4 3 2 1 13 12 11 10 9 8 7 0.1A 30VDC Operating power supply 100 to 240VAC 50/60Hz Measured voltage input 1 2 Load side Power supply side RS485 Pulse output Pulse input E – +– – ++ P0 P2 P1 *2 6 5 4 3 2 1 13 12 11 10 9 8 7 0.1A 30VDC Operating power supply 100 to 240VAC 50/60Hz Measured voltage input Direction of CT L K CT1 CT2 1 2 3 R S T R N T Load side Power supply side • Three-phase four-wire system *Three CTs are required. RS485 Pulse output Pulse input E – +– – ++ P0 P2 P3 P1 6 5 4 3 2 1 13 12 11 10 9 8 7 0.1A 30VDC Operating power supply 100 to 240VAC 50/60Hz Measured voltage input Direction of CT L K 2 1 3 4 S R T N Load side Power supply side CT1 CT2 CT3 *1. Do not wire to T, Y terminal. They are connected internal. *2. Do not wire to Y terminal. They are connected internal. E VT R E R S T R N T 1 1 2 2 3 VT R T E N R S T VT R TY Eco-POWER METER (Secondary side) • Single-phase two-wire system • Single-phase three-wire system/ Three-phase three-wire system • Three-phase four-wire system (Primary side) Load side Load side Load side Power supply side Power supply side Power supply side Eco-POWER METER (Secondary side) (Primary side) Eco-POWER METER (Secondary side) (Primary side) *Grounding the secondary side of voltage transformer (VT) and current transformer (CT) is not necessary with low voltage circuit. CT1 *Do not connect to CT2 and CT3. CT1 • Single-phase two-wire system • Single-phase three-wire system/Three-phase three-wire system *One CT is required. *Two CTs are required. • Three-phase four-wire system *Three CTs are required. CT3 CT1 CT2 Direction of CT L K Direction of CT L K Direction of CT L K RS485 Pulse output Pulse input E – +– – ++ P0 P1 N.C. *1 *1 7 6 5 4 3 2 1 14 13 12 11 10 9 8 0.1A 30VDC Operating power supply 100 to 240VAC 50/60Hz Measured voltage input 1 2 Load side Power supply side *Do not connect to CT3. CT1 CT2 CT1 CT2 1 2 3 R S T R N T Load side Power supply side RS485 Pulse output Pulse input 0.1A 30VDC P0 P2 P1 N.C. *2 7 6 5 4 3 2 1 Operating power supply 100 to 240VAC 50/60Hz Measured voltage input E – +– – ++ 14 13 12 11 10 9 8 RS485 Pulse output Pulse input E – +– – ++ P0 P2 P3 P1 N.C. 7 6 5 4 3 2 1 14 13 12 11 10 9 8 0.1A 30VDC Operating power supply 100 to 240VAC 50/60Hz Measured voltage input 2 1 3 4 S R T N Load side Power supply side CT1 CT2 CT3 *1. Do not wire to Y, U terminal. They are connected internal. *2. Do not wire to U terminal. They are connected internal. All Rights Reserved © C OPYRIGHT Panasonic Electric Works Co., Ltd. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |